Energy Performance Certificate

2/4 , 210 Prospecthill Circus , GLASGOW, G42 0LF

EPC Report

Energy rating

Current: 85 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 89 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 89 Potential: 89
Field Value
Id 4116965
BUILDING REFERENCE NUMBER 1234952009
OSG REFERENCE NUMBER
ADDRESS1 2/4
ADDRESS2 210 Prospecthill Circus
ADDRESS3 GLASGOW
POSTCODE G42 0LF
INSPECTION DATE 2016-06-01
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2016-06-01
ENERGY CONSUMPTION CURRENT 75.00
TOTAL FLOOR AREA 70
3 YR ENERGY COST CURRENT 903.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 85
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 85
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 89
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 89
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 13.00
IMPROVEMENTS
WALL DESCRIPTION Average thermal transmittance 0.16 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 5.0 m³/h.m² (assumed)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 0.90
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 495.0000
HEATING COST POTENTIAL 495.0000
HOT WATER COST CURRENT 264.00
HOT WATER COST POTENTIAL 264.00
LIGHTING COST CURRENT 144.00
LIGHTING COST POTENTIAL 144.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 1046
WATER HEATING DEMAND 1788
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT
DATA ZONE S01003150 (Toryglen and Oatlands)
ENERGY CONSUMPTION POTENTIAL 75.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL mid floor
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL Glasgow City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL Gas: mains gas
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
TENURE owner-occupied
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QSMH
CONSTITUENCY LABEL Southside Central
WIND TURBINE COUNT 0
BUILT FORM Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01010019 (Toryglen and Oatlands - 04)
CREATED AT 01/06/2016 15:44:26
REPORT REFERENCE NUMBER 9902-6590-3239-6400-1663
Source file Q2 2016.csv
Address display 2/4 , 210 Prospecthill Circus , GLASGOW
Nation scotland