Energy Performance Certificate

1D LAWSON STREET , KIRKCALDY, KY1 3JZ

EPC Report

Energy rating

Current: 79 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 83 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 83 Potential: 83
Field Value
Id 4119623
BUILDING REFERENCE NUMBER 1234952519
OSG REFERENCE NUMBER 320316991
ADDRESS1 1D LAWSON STREET
ADDRESS2
ADDRESS3 KIRKCALDY
POSTCODE KY1 3JZ
INSPECTION DATE 2016-06-08
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-15
ENERGY CONSUMPTION CURRENT 153.00
TOTAL FLOOR AREA 45
3 YR ENERGY COST CURRENT 1113.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 79
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 79
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 83
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 83
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 27.00
IMPROVEMENTS
WALL DESCRIPTION Timber frame, as built, insulated (assumed)
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.20
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 810.0000
HEATING COST POTENTIAL 810.0000
HOT WATER COST CURRENT 204.00
HOT WATER COST POTENTIAL 204.00
LIGHTING COST CURRENT 99.00
LIGHTING COST POTENTIAL 99.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 2225
WATER HEATING DEMAND 1391
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1950-1964
FLOOR HEIGHT 3.32
DATA ZONE S01002779 (Kirkcaldy Gallatown and Sinclairtown)
ENERGY CONSUMPTION POTENTIAL 153.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR no corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Fife
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2110
MECHANICAL VENTILATION mechanical, extract only
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QRMN
CONSTITUENCY LABEL Kirkcaldy East
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01009535 (Gallatown West)
CREATED AT 15/06/2016 15:45:45
REPORT REFERENCE NUMBER 9902-2585-3229-6401-1663
Source file Q2 2016.csv
Address display 1D LAWSON STREET , KIRKCALDY
Nation scotland