Energy Performance Certificate

1F2 , 13 WESTFIELD ROAD , EDINBURGH, EH11 2QS

EPC Report

Energy rating

Current: 50 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 45 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 85 Potential: 85
Field Value
Id 5124254
BUILDING REFERENCE NUMBER 1000831766
OSG REFERENCE NUMBER 906285316
ADDRESS1 1F2
ADDRESS2 13 WESTFIELD ROAD
ADDRESS3 EDINBURGH
POSTCODE EH11 2QS
INSPECTION DATE 2024-10-14
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2024-10-16
ENERGY CONSUMPTION CURRENT 534.00
TOTAL FLOOR AREA 42
3 YR ENERGY COST CURRENT 4554.0000
3 YR ENERGY SAVINGS POTENTIAL 3327.0000
CURRENT ENERGY EFFICIENCY 50
CURRENT ENERGY RATING E
POTENTIAL ENERGY EFFICIENCY 81
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 45
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 85
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 90.00
IMPROVEMENTS Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 254; Energy Rating after improvement: D 57; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Change heating to gas condensing boiler; Indicative Cost: £3,000 - £7,000; Typical Saving: 285; Energy Rating after improvement: B 81; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | Description: Insulate hot water cylinder with 80 mm jacket; Indicative Cost: £15 - £30; Typical Saving: 547; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 22; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 73; Green Deal Eligible: N |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Poor
WALL ENV EFF Poor | Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.80
CO2 EMISSIONS POTENTIAL 2.80
HEATING COST CURRENT 1125.0000
HEATING COST POTENTIAL 645.0000
HOT WATER COST CURRENT 3171.00
HOT WATER COST POTENTIAL 432.00
LIGHTING COST CURRENT 258.00
LIGHTING COST POTENTIAL 150.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 2346
WATER HEATING DEMAND 4676
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -1591
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 2.8
DATA ZONE S01002031 (Gorgie West)
ENERGY CONSUMPTION POTENTIAL 131.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
LOW ENERGY LIGHTING 50.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2401
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 6.46
CONSTITUENCY 00QPMG
CONSTITUENCY LABEL Sighthill/Gorgie
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008494 (Gorgie West - 03)
CREATED AT 16/10/2024 17:20:27
REPORT REFERENCE NUMBER 9846-1908-6200-7014-3200
Source file Q4 2024.csv
Address display 1F2 , 13 WESTFIELD ROAD , EDINBURGH
Nation scotland