Energy Performance Certificate

56 BROAD CAIRN COURT , MOTHERWELL, ML1 2PE

EPC Report

Energy rating

Current: 81 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 83 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 85 Potential: 85
Field Value
Id 3807588
BUILDING REFERENCE NUMBER 1001471339
OSG REFERENCE NUMBER
ADDRESS1 56 BROAD CAIRN COURT
ADDRESS2 MOTHERWELL
ADDRESS3
POSTCODE ML1 2PE
INSPECTION DATE 2020-03-10
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2020-03-11
ENERGY CONSUMPTION CURRENT 121.00
TOTAL FLOOR AREA 73
3 YR ENERGY COST CURRENT 1266.0000
3 YR ENERGY SAVINGS POTENTIAL 84.0000
CURRENT ENERGY EFFICIENCY 81
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 82
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 83
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 85
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 21.00
IMPROVEMENTS Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 28; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 85; Green Deal Eligible: Y |
WALL DESCRIPTION Timber frame, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.50
CO2 EMISSIONS POTENTIAL 0.10
HEATING COST CURRENT 651.0000
HEATING COST POTENTIAL 618.0000
HOT WATER COST CURRENT 399.00
HOT WATER COST POTENTIAL 348.00
LIGHTING COST CURRENT 216.00
LIGHTING COST POTENTIAL 216.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 1943
WATER HEATING DEMAND 2421
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 2003-2007
FLOOR HEIGHT 2.4
DATA ZONE S01004549 (Netherton and Kirkhill)
ENERGY CONSUMPTION POTENTIAL 109.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 8
LOW ENERGY LIGHTING 89.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL North Lanarkshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 10.31
CONSTITUENCY 00QZMT
CONSTITUENCY LABEL Motherwell South East and Ravenscraig
WIND TURBINE COUNT 0
BUILT FORM End-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01011368 (Muirhouse - 01)
CREATED AT 11/03/2020 10:02:21
REPORT REFERENCE NUMBER 9809-1014-3207-3310-7204
Source file Q1 2020.csv
Address display 56 BROAD CAIRN COURT , MOTHERWELL
Nation scotland