Energy Performance Certificate

G/1 , 9 PENTLAND CRESCENT , DUNDEE, DD2 2BU

EPC Report

Energy rating

Current: 57 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 43 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 58 Potential: 58
Field Value
Id 5125643
BUILDING REFERENCE NUMBER 1000879035
OSG REFERENCE NUMBER 9059029583
ADDRESS1 G/1
ADDRESS2 9 PENTLAND CRESCENT
ADDRESS3 DUNDEE
POSTCODE DD2 2BU
INSPECTION DATE 2024-10-10
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2024-10-10
ENERGY CONSUMPTION CURRENT 525.00
TOTAL FLOOR AREA 60
3 YR ENERGY COST CURRENT 6594.0000
3 YR ENERGY SAVINGS POTENTIAL 3183.0000
CURRENT ENERGY EFFICIENCY 57
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 75
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 43
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 58
POTENTIAL ENVIRONMENTAL RATING D
CO2 EMISS CURR PER FLOOR AREA 89.00
IMPROVEMENTS Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 390; Energy Rating after improvement: D 65; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 57; Energy Rating after improvement: D 66; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 614; Energy Rating after improvement: C 75; Environmental Rating after improvement: D 58; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, filled cavity
WALL ENERGY EFF Average
WALL ENV EFF Average
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 5.30
CO2 EMISSIONS POTENTIAL 1.60
HEATING COST CURRENT 4242.0000
HEATING COST POTENTIAL 2277.0000
HOT WATER COST CURRENT 1968.00
HOT WATER COST POTENTIAL 750.00
LIGHTING COST CURRENT 384.00
LIGHTING COST POTENTIAL 384.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 8037
WATER HEATING DEMAND 1940
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1950-1964
FLOOR HEIGHT 2.4
DATA ZONE S01001115 (Balgay)
ENERGY CONSUMPTION POTENTIAL 360.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Dundee City
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2401
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (private)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH 10
CONSTITUENCY 00QJMC
CONSTITUENCY LABEL West End
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01007834 (Balgay - 01)
CREATED AT 10/10/2024 13:28:33
REPORT REFERENCE NUMBER 9805-1908-3200-0094-7204
Source file Q4 2024.csv
Address display G/1 , 9 PENTLAND CRESCENT , DUNDEE