Energy Performance Certificate
FLAT 6/11 DALHOUSIE COURT , 42 WEST GRAHAM STREET , GLASGOW, G4 9LH
Energy rating
Current: 76 C | Potential: 80 C
Environmental impact (CO₂)
Current: 65
| Potential: 70
| Field | Value |
|---|---|
| Id | 4375737 |
| BUILDING REFERENCE NUMBER | 1000906820 |
| OSG REFERENCE NUMBER | 906700114289 |
| ADDRESS1 | FLAT 6/11 DALHOUSIE COURT |
| ADDRESS2 | 42 WEST GRAHAM STREET |
| ADDRESS3 | GLASGOW |
| POSTCODE | G4 9LH |
| INSPECTION DATE | 2024-05-17 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2024-05-17 |
| ENERGY CONSUMPTION CURRENT | 261.00 |
| TOTAL FLOOR AREA | 68 |
| 3 YR ENERGY COST CURRENT | 3372.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 579.0000 |
| CURRENT ENERGY EFFICIENCY | 76 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 80 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 65 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 70 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 44.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 23; Energy Rating after improvement: C 77; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 38; Energy Rating after improvement: C 78; Environmental Rating after improvement: D 66; Green Deal Eligible: N | Description: High heat retention storage heaters; Indicative Cost: £1,200 - £1,800; Typical Saving: 132; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 57% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.00 |
| CO2 EMISSIONS POTENTIAL | 0.40 |
| HEATING COST CURRENT | 1764.0000 |
| HEATING COST POTENTIAL | 1455.0000 |
| HOT WATER COST CURRENT | 1095.00 |
| HOT WATER COST POTENTIAL | 978.00 |
| LIGHTING COST CURRENT | 513.00 |
| LIGHTING COST POTENTIAL | 360.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3280 |
| WATER HEATING DEMAND | 2024 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1992-1998 |
| FLOOR HEIGHT | 2.32 |
| DATA ZONE | S01003446 (City Centre West) |
| ENERGY CONSUMPTION POTENTIAL | 228.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 57.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 06 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 9.51 |
| CONSTITUENCY | 00QSMK |
| CONSTITUENCY LABEL | Anderston/City |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Enclosed End-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010269 (City Centre West - 04) |
| CREATED AT | 17/05/2024 13:51:36 |
| REPORT REFERENCE NUMBER | 9730-1009-2205-8564-0200 |
| Source file | Q2 2024.csv |
| Address display | FLAT 6/11 DALHOUSIE COURT , 42 WEST GRAHAM STREET , GLASGOW |
| Nation | scotland |