Energy Performance Certificate
2 MORLICH SQUARE , FORRES, IV36 1FR
Energy rating
Current: 91 B | Potential: 94 A
Environmental impact (CO₂)
Current: 89
| Potential: 93
| Field | Value |
|---|---|
| Id | 3970655 |
| BUILDING REFERENCE NUMBER | 1001779499 |
| OSG REFERENCE NUMBER | 133011781 |
| ADDRESS1 | 2 MORLICH SQUARE |
| ADDRESS2 | — |
| ADDRESS3 | FORRES |
| POSTCODE | IV36 1FR |
| INSPECTION DATE | 2024-03-10 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2024-03-14 |
| ENERGY CONSUMPTION CURRENT | 82.00 |
| TOTAL FLOOR AREA | 96 |
| 3 YR ENERGY COST CURRENT | 3480.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 435.0000 |
| CURRENT ENERGY EFFICIENCY | 91 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 94 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 89 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 93 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 15.00 |
| IMPROVEMENTS | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 89; Energy Rating after improvement: A 93; Environmental Rating after improvement: B 91; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 55; Energy Rating after improvement: A 94; Environmental Rating after improvement: A 93; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, with external insulation |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Mostly double glazing |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 92% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.40 |
| CO2 EMISSIONS POTENTIAL | 0.40 |
| HEATING COST CURRENT | 2517.0000 |
| HEATING COST POTENTIAL | 2250.0000 |
| HOT WATER COST CURRENT | 501.00 |
| HOT WATER COST POTENTIAL | 333.00 |
| LIGHTING COST CURRENT | 462.00 |
| LIGHTING COST POTENTIAL | 462.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 8137 |
| WATER HEATING DEMAND | 1964 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01004261 (IZ Seven) |
| ENERGY CONSUMPTION POTENTIAL | 56.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 11 |
| LOW ENERGY LIGHTING | 92.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 4 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Moray |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Peak Power: 3.28; Orientation: South West; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QXMH |
| CONSTITUENCY LABEL | Forres |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01011163 (Forres South West and Mannachie - 05) |
| CREATED AT | 14/03/2024 10:03:23 |
| REPORT REFERENCE NUMBER | 9714-9727-4100-0980-7292 |
| Source file | Q1 2024.csv |
| Address display | 2 MORLICH SQUARE , FORRES |
| Nation | scotland |