Energy Performance Certificate
FLAT 3/1 , 40 BLANTYRE STREET , GLASGOW, G3 8AR
Energy rating
Current: 59 D | Potential: 71 C
Environmental impact (CO₂)
Current: 64
| Potential: 80
| Field | Value |
|---|---|
| Id | 5163062 |
| BUILDING REFERENCE NUMBER | 1000827914 |
| OSG REFERENCE NUMBER | 906700012960 |
| ADDRESS1 | FLAT 3/1 |
| ADDRESS2 | 40 BLANTYRE STREET |
| ADDRESS3 | GLASGOW |
| POSTCODE | G3 8AR |
| INSPECTION DATE | 2025-12-12 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-12-12 |
| ENERGY CONSUMPTION CURRENT | 343.00 |
| TOTAL FLOOR AREA | 36 |
| 3 YR ENERGY COST CURRENT | 2973.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 987.0000 |
| CURRENT ENERGY EFFICIENCY | 59 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 71 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 64 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 60.00 |
| IMPROVEMENTS | Description: Internal or external wall insulation; Indicative Cost: £7,500 - £11,000; Typical Saving: 129; Energy Rating after improvement: D 64; Environmental Rating after improvement: C 71; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £5,000 - £10,000; Typical Saving: 61; Energy Rating after improvement: D 66; Environmental Rating after improvement: C 74; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £220 - £250; Typical Saving: 31; Energy Rating after improvement: D 68; Environmental Rating after improvement: C 76; Green Deal Eligible: N | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £4,500 - £6,000; Typical Saving: 67; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 80; Green Deal Eligible: N | Description: Low energy lighting for all fixed outlets; Indicative Cost: £300 - £350; Typical Saving: 25; Energy Rating after improvement: D 67; Environmental Rating after improvement: C 75; Green Deal Eligible: N | Description: Draughtproofing; Indicative Cost: £150 - £250; Typical Saving: 16; Energy Rating after improvement: D 67; Environmental Rating after improvement: C 75; Green Deal Eligible: N | |
| WALL DESCRIPTION | Sandstone, as built, no insulation (assumed) | System built, as built, insulated (assumed) |
| WALL ENERGY EFF | Poor | Good |
| WALL ENV EFF | Poor | Good |
| ROOF DESCRIPTION | Pitched, insulated (assumed) |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | — |
| WINDOWS ENERGY EFF | — |
| WINDOWS ENV EFF | — |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Below average lighting efficiency |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.20 |
| CO2 EMISSIONS POTENTIAL | 1.00 |
| HEATING COST CURRENT | 2184.0000 |
| HEATING COST POTENTIAL | 1284.0000 |
| HOT WATER COST CURRENT | 588.00 |
| HOT WATER COST POTENTIAL | 588.00 |
| LIGHTING COST CURRENT | 201.00 |
| LIGHTING COST POTENTIAL | 114.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 7246.14 |
| WATER HEATING DEMAND | 1443.82 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1919-1929 |
| FLOOR HEIGHT | — |
| DATA ZONE | S01003450 (Finnieston and Kelvinhaugh) |
| ENERGY CONSUMPTION POTENTIAL | 199.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 0 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | — |
| MAIN FUEL | — |
| MAIN HEATING CONTROLS | — |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 4.2 |
| CONSTITUENCY | 00QSMK |
| CONSTITUENCY LABEL | Anderston/City |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | — |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010282 (Finnieston and Kelvinhaugh - 01) |
| CREATED AT | 12/12/2025 11:50:25 |
| REPORT REFERENCE NUMBER | 9624-1908-1202-9575-2204 |
| Source file | Q4 2025.csv |
| Address display | FLAT 3/1 , 40 BLANTYRE STREET , GLASGOW |
| Nation | scotland |