Energy Performance Certificate
FLAT 3/1 , 9 GLENMORE PLACE , GLASGOW, G42 0EA
Energy rating
Current: 71 C | Potential: 83 B
Environmental impact (CO₂)
Current: 74
| Potential: 73
| Field | Value |
|---|---|
| Id | 4003186 |
| BUILDING REFERENCE NUMBER | 1000753438 |
| OSG REFERENCE NUMBER | 906700426214 |
| ADDRESS1 | FLAT 3/1 |
| ADDRESS2 | 9 GLENMORE PLACE |
| ADDRESS3 | GLASGOW |
| POSTCODE | G42 0EA |
| INSPECTION DATE | 2025-02-10 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-02-11 |
| ENERGY CONSUMPTION CURRENT | 208.00 |
| TOTAL FLOOR AREA | 57 |
| 3 YR ENERGY COST CURRENT | 2826.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1104.0000 |
| CURRENT ENERGY EFFICIENCY | 71 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 74 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 73 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 35.00 |
| IMPROVEMENTS | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 368; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.00 |
| CO2 EMISSIONS POTENTIAL | -0.10 |
| HEATING COST CURRENT | 1311.0000 |
| HEATING COST POTENTIAL | 759.0000 |
| HOT WATER COST CURRENT | 1305.00 |
| HOT WATER COST POTENTIAL | 726.00 |
| LIGHTING COST CURRENT | 210.00 |
| LIGHTING COST POTENTIAL | 237.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 1808 |
| WATER HEATING DEMAND | 1800 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 2008 onwards |
| FLOOR HEIGHT | 2.39 |
| DATA ZONE | S01003142 (Toryglen and Oatlands) |
| ENERGY CONSUMPTION POTENTIAL | 214.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2602 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 9.87 |
| CONSTITUENCY | 00QSMH |
| CONSTITUENCY LABEL | Southside Central |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010018 (Toryglen and Oatlands - 03) |
| CREATED AT | 11/02/2025 14:57:36 |
| REPORT REFERENCE NUMBER | 9608-1007-3202-4635-5200 |
| Source file | Q1 2025.csv |
| Address display | FLAT 3/1 , 9 GLENMORE PLACE , GLASGOW |
| Nation | scotland |