Energy Performance Certificate

2F1 , 13 YEAMAN PLACE , EDINBURGH, EH11 1BR

EPC Report

Energy rating

Current: 57 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 48 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 76 Potential: 76
Field Value
Id 3900970
BUILDING REFERENCE NUMBER 1000076435
OSG REFERENCE NUMBER 906277837
ADDRESS1 2F1
ADDRESS2 13 YEAMAN PLACE
ADDRESS3 EDINBURGH
POSTCODE EH11 1BR
INSPECTION DATE 2023-03-13
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-03-13
ENERGY CONSUMPTION CURRENT 520.00
TOTAL FLOOR AREA 40
3 YR ENERGY COST CURRENT 4791.0000
3 YR ENERGY SAVINGS POTENTIAL 3384.0000
CURRENT ENERGY EFFICIENCY 57
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 85
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 48
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 76
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 88.00
IMPROVEMENTS Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 340; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 62; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £10; Typical Saving: 32; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 63; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £800 - £1,200; Typical Saving: 681; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 75; Energy Rating after improvement: B 85; Environmental Rating after improvement: C 76; Green Deal Eligible: Y |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Poor
WALL ENV EFF Poor | Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.50
CO2 EMISSIONS POTENTIAL 1.90
HEATING COST CURRENT 1761.0000
HEATING COST POTENTIAL 528.0000
HOT WATER COST CURRENT 2682.00
HOT WATER COST POTENTIAL 648.00
LIGHTING COST CURRENT 348.00
LIGHTING COST POTENTIAL 231.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 3489
WATER HEATING DEMAND 3004
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -2020
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 2.91
DATA ZONE S01002046 (Dalry and Fountainbridge)
ENERGY CONSUMPTION POTENTIAL 234.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 2
LOW ENERGY LIGHTING 50.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2401
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 5.55
CONSTITUENCY 00QPMJ
CONSTITUENCY LABEL Fountainbridge/Craiglockhart
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008652 (Dalry and Fountainbridge - 02)
CREATED AT 13/03/2023 18:12:21
REPORT REFERENCE NUMBER 9475-1000-3207-4367-7204
Source file Q1 2023.csv
Address display 2F1 , 13 YEAMAN PLACE , EDINBURGH
Nation scotland