Energy Performance Certificate

60A BALLINDEAN PLACE , DUNDEE, DD4 8PF

EPC Report

Energy rating

Current: 75 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 77 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 81 Potential: 81
Field Value
Id 3911410
BUILDING REFERENCE NUMBER 1000775292
OSG REFERENCE NUMBER 9059050677
ADDRESS1 60A BALLINDEAN PLACE
ADDRESS2
ADDRESS3 DUNDEE
POSTCODE DD4 8PF
INSPECTION DATE 2023-01-13
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-01-13
ENERGY CONSUMPTION CURRENT 204.00
TOTAL FLOOR AREA 46
3 YR ENERGY COST CURRENT 1419.0000
3 YR ENERGY SAVINGS POTENTIAL 177.0000
CURRENT ENERGY EFFICIENCY 75
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 78
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 77
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 81
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 36.00
IMPROVEMENTS Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 59; Energy Rating after improvement: C 78; Environmental Rating after improvement: B 81; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, filled cavity
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.70
CO2 EMISSIONS POTENTIAL 0.30
HEATING COST CURRENT 1029.0000
HEATING COST POTENTIAL 852.0000
HOT WATER COST CURRENT 234.00
HOT WATER COST POTENTIAL 234.00
LIGHTING COST CURRENT 156.00
LIGHTING COST POTENTIAL 156.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 4457
WATER HEATING DEMAND 1617
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1984-1991
FLOOR HEIGHT 2.28
DATA ZONE S01001203 (Douglas West)
ENERGY CONSUMPTION POTENTIAL 167.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR no corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Dundee City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (social)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QJMG
CONSTITUENCY LABEL East End
WIND TURBINE COUNT 0
BUILT FORM End-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01007744 (Douglas West - 02)
CREATED AT 13/01/2023 14:45:42
REPORT REFERENCE NUMBER 9472-1007-9209-2857-7204
Source file Q1 2023.csv
Address display 60A BALLINDEAN PLACE , DUNDEE
Nation scotland