Energy Performance Certificate
113 STEWART ROAD , FALKIRK, FK2 7AQ
Energy rating
Current: 17 G | Potential: 59 D
Environmental impact (CO₂)
Current: 29
| Potential: 36
| Field | Value |
|---|---|
| Id | 4985204 |
| BUILDING REFERENCE NUMBER | 1000872552 |
| OSG REFERENCE NUMBER | 136028489 |
| ADDRESS1 | 113 STEWART ROAD |
| ADDRESS2 | — |
| ADDRESS3 | FALKIRK |
| POSTCODE | FK2 7AQ |
| INSPECTION DATE | 2020-10-19 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-10-19 |
| ENERGY CONSUMPTION CURRENT | 758.00 |
| TOTAL FLOOR AREA | 50 |
| 3 YR ENERGY COST CURRENT | 6927.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 3771.0000 |
| CURRENT ENERGY EFFICIENCY | 17 |
| CURRENT ENERGY RATING | G |
| POTENTIAL ENERGY EFFICIENCY | 59 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 29 |
| CURRENT ENVIRONMENTAL RATING | F |
| ENVIRONMENT IMPACT POTENTIAL | 36 |
| POTENTIAL ENVIRONMENTAL RATING | F |
| CO2 EMISS CURR PER FLOOR AREA | 128.00 |
| IMPROVEMENTS | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 98; Energy Rating after improvement: D 59; Environmental Rating after improvement: F 36; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 296; Energy Rating after improvement: F 24; Environmental Rating after improvement: F 35; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 28; Energy Rating after improvement: F 25; Environmental Rating after improvement: F 35; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £800 - £1,200; Typical Saving: 835; Energy Rating after improvement: D 55; Environmental Rating after improvement: F 33; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 57% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.40 |
| CO2 EMISSIONS POTENTIAL | 1.00 |
| HEATING COST CURRENT | 5718.0000 |
| HEATING COST POTENTIAL | 2460.0000 |
| HOT WATER COST CURRENT | 1023.00 |
| HOT WATER COST POTENTIAL | 486.00 |
| LIGHTING COST CURRENT | 186.00 |
| LIGHTING COST POTENTIAL | 210.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 10191 |
| WATER HEATING DEMAND | 1826 |
| IMPACT LOFT INSULATION | -4669 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -1941 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.7 |
| DATA ZONE | S01002459 (Grahamston) |
| ENERGY CONSUMPTION POTENTIAL | 635.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 57.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Falkirk |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2602 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 6 |
| CONSTITUENCY | 00QQMF |
| CONSTITUENCY LABEL | Falkirk North |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01009142 (Falkirk - Grahamston - 05) |
| CREATED AT | 19/10/2020 15:35:06 |
| REPORT REFERENCE NUMBER | 9412-1908-5200-5320-7204 |
| Source file | Q4 2020.csv |
| Address display | 113 STEWART ROAD , FALKIRK |
| Nation | scotland |