Energy Performance Certificate

98 Barton Terrace , Fauldhouse , Bathgate, EH47 9LL

EPC Report

Energy rating

Current: 5 G | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 5 G Current: 5 G 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 20 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 81 Potential: 81
Field Value
Id 4467288
BUILDING REFERENCE NUMBER 1000488489
OSG REFERENCE NUMBER 200004150667
ADDRESS1 98 Barton Terrace
ADDRESS2 Fauldhouse
ADDRESS3 Bathgate
POSTCODE EH47 9LL
INSPECTION DATE 2016-06-15
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-07-06
ENERGY CONSUMPTION CURRENT 745.00
TOTAL FLOOR AREA 129
3 YR ENERGY COST CURRENT 14502.0000
3 YR ENERGY SAVINGS POTENTIAL 11694.0000
CURRENT ENERGY EFFICIENCY 5
CURRENT ENERGY RATING G
POTENTIAL ENERGY EFFICIENCY 84
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 20
CURRENT ENVIRONMENTAL RATING G
ENVIRONMENT IMPACT POTENTIAL 81
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 126.00
IMPROVEMENTS Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 29; Energy Rating after improvement: F 30; Environmental Rating after improvement: E 40; Green Deal Eligible: N | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 249; Energy Rating after improvement: B 84; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 965; Energy Rating after improvement: F 21; Environmental Rating after improvement: F 32; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 541; Energy Rating after improvement: F 30; Environmental Rating after improvement: E 39; Green Deal Eligible: Y | Description: Change heating to gas condensing boiler; Indicative Cost: £3,000 - £7,000; Typical Saving: 1967; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 35; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Flat roof insulation; Indicative Cost: £850 - £1,500; Typical Saving: 301; Energy Rating after improvement: G 8; Environmental Rating after improvement: F 22; Green Deal Eligible: Y | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 59; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 74; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALL ENERGY EFF Poor
WALL ENV EFF Poor
ROOF DESCRIPTION Flat, limited insulation (assumed) | Pitched, 200 mm loft insulation
ROOF ENERGY EFF Very Poor | Good
ROOF ENV EFF Very Poor | Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 23% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 16.00
CO2 EMISSIONS POTENTIAL 12.70
HEATING COST CURRENT 12447.0000
HEATING COST POTENTIAL 2349.0000
HOT WATER COST CURRENT 1662.00
HOT WATER COST POTENTIAL 237.00
LIGHTING COST CURRENT 393.00
LIGHTING COST POTENTIAL 222.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 26871
WATER HEATING DEMAND 3588
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -6087
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1930-1949
FLOOR HEIGHT 2.55
DATA ZONE S01006300 (Fauldhouse)
ENERGY CONSUMPTION POTENTIAL 142.00
EXTENSION COUNT 1
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 3
LOW ENERGY LIGHTING 23.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 5
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL West Lothian
MAINS GAS FLAG
MAIN HEATING CATEGORY none
MAIN FUEL no heating/hot-water system or data is from a community network
MAIN HEATING CONTROLS 2699
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00RHMF
CONSTITUENCY LABEL Fauldhouse and the Breich Valley
WIND TURBINE COUNT 0
BUILT FORM Detached
PROPERTY TYPE Bungalow
DATA ZONE 2011 S01013247 (Fauldhouse - 05)
CREATED AT 06/07/2016 21:54:42
REPORT REFERENCE NUMBER 9400-2854-0829-6098-1663
Source file Q3 2016.csv
Address display 98 Barton Terrace , Fauldhouse , Bathgate
Nation scotland