Energy Performance Certificate

3 DUNTAYLOR AVENUE , ABERFELDY, PH15 2BX

EPC Report

Energy rating

Current: 68 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 63 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 79 Potential: 79
Field Value
Id 4782745
BUILDING REFERENCE NUMBER 1001237907
OSG REFERENCE NUMBER 124052040
ADDRESS1 3 DUNTAYLOR AVENUE
ADDRESS2
ADDRESS3 ABERFELDY
POSTCODE PH15 2BX
INSPECTION DATE 2024-08-15
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2024-08-15
ENERGY CONSUMPTION CURRENT 281.00
TOTAL FLOOR AREA 113
3 YR ENERGY COST CURRENT 6321.0000
3 YR ENERGY SAVINGS POTENTIAL 1395.0000
CURRENT ENERGY EFFICIENCY 68
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 83
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 63
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 79
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 50.00
IMPROVEMENTS Description: Low energy lighting for all fixed outlets; Indicative Cost: £25; Typical Saving: 30; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 69; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 83; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 431; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 297; Energy Rating after improvement: C 72; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 54; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 72; Green Deal Eligible: Y |
WALL DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALL ENERGY EFF Average
WALL ENV EFF Average
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 72% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 5.60
CO2 EMISSIONS POTENTIAL 2.10
HEATING COST CURRENT 5301.0000
HEATING COST POTENTIAL 4176.0000
HOT WATER COST CURRENT 534.00
HOT WATER COST POTENTIAL 372.00
LIGHTING COST CURRENT 486.00
LIGHTING COST POTENTIAL 378.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 18460
WATER HEATING DEMAND 2144
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1965-1975
FLOOR HEIGHT 2.3
DATA ZONE S01005131 (Rannoch and Aberfeldy)
ENERGY CONSUMPTION POTENTIAL 174.00
EXTENSION COUNT 1
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 13
LOW ENERGY LIGHTING 72.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 4
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 4
LOCAL AUTHORITY LABEL Perth and Kinross
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00RBMD
CONSTITUENCY LABEL Highland
WIND TURBINE COUNT 0
BUILT FORM Detached
PROPERTY TYPE Bungalow
DATA ZONE 2011 S01012015 (Rannoch and Aberfeldy - 03)
CREATED AT 15/08/2024 17:41:23
REPORT REFERENCE NUMBER 9357-1012-0208-9074-3200
Source file Q3 2024.csv
Address display 3 DUNTAYLOR AVENUE , ABERFELDY
Nation scotland