Energy Performance Certificate

FLAT 1/1 , 126 ONSLOW DRIVE , GLASGOW, G31 2PZ

EPC Report

Energy rating

Current: 67 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 62 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 81 Potential: 81
Field Value
Id 4091465
BUILDING REFERENCE NUMBER 1000320759
OSG REFERENCE NUMBER 906700192437
ADDRESS1 FLAT 1/1
ADDRESS2 126 ONSLOW DRIVE
ADDRESS3 GLASGOW
POSTCODE G31 2PZ
INSPECTION DATE 2016-06-21
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-21
ENERGY CONSUMPTION CURRENT 243.00
TOTAL FLOOR AREA 93
3 YR ENERGY COST CURRENT 2796.0000
3 YR ENERGY SAVINGS POTENTIAL 1239.0000
CURRENT ENERGY EFFICIENCY 67
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 81
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 62
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 81
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 43.00
IMPROVEMENTS Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 136; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 107; Energy Rating after improvement: C 80; Environmental Rating after improvement: C 80; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 119; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 21; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 75; Green Deal Eligible: N | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 30; Energy Rating after improvement: B 81; Environmental Rating after improvement: B 81; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed) | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Very Poor | Poor
WALL ENV EFF Poor | Very Poor | Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 4.00
CO2 EMISSIONS POTENTIAL 2.00
HEATING COST CURRENT 2118.0000
HEATING COST POTENTIAL 1029.0000
HOT WATER COST CURRENT 408.00
HOT WATER COST POTENTIAL 339.00
LIGHTING COST CURRENT 270.00
LIGHTING COST POTENTIAL 189.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 9264
WATER HEATING DEMAND 2205
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -2176
IMPACT SOLID WALL INSULATION -1905
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 3.46
DATA ZONE S01003395 (Dennistoun North and Alexandra Parade)
ENERGY CONSUMPTION POTENTIAL 120.00
EXTENSION COUNT 1
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
LOW ENERGY LIGHTING 57.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 4
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 4
LOCAL AUTHORITY LABEL Glasgow City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 60
GLAZED TYPE double glazing, unknown install date
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 6.89
CONSTITUENCY 00QSMT
CONSTITUENCY LABEL East Centre
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01010237 (Dennistoun North - 04)
CREATED AT 21/06/2016 15:41:45
REPORT REFERENCE NUMBER 9300-5297-0029-0025-1663
Source file Q2 2016.csv
Address display FLAT 1/1 , 126 ONSLOW DRIVE , GLASGOW
Nation scotland