Energy Performance Certificate
FLAT 0/2 , 39 ST MUNGO AVENUE , GLASGOW, G4 0PH
Energy rating
Current: 41 E | Potential: 77 C
Environmental impact (CO₂)
Current: 48
| Potential: 61
| Field | Value |
|---|---|
| Id | 4102487 |
| BUILDING REFERENCE NUMBER | 1001332619 |
| OSG REFERENCE NUMBER | 906700104748 |
| ADDRESS1 | FLAT 0/2 |
| ADDRESS2 | 39 ST MUNGO AVENUE |
| ADDRESS3 | GLASGOW |
| POSTCODE | G4 0PH |
| INSPECTION DATE | 2016-06-24 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-24 |
| ENERGY CONSUMPTION CURRENT | 364.00 |
| TOTAL FLOOR AREA | 87 |
| 3 YR ENERGY COST CURRENT | 4752.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2853.0000 |
| CURRENT ENERGY EFFICIENCY | 41 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 48 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 61 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 62.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 351; Energy Rating after improvement: E 54; Environmental Rating after improvement: D 58; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 20; Energy Rating after improvement: D 55; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £55; Typical Saving: 32; Energy Rating after improvement: D 56; Environmental Rating after improvement: D 60; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £2,000 - £3,000; Typical Saving: 549; Energy Rating after improvement: C 77; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, with external insulation | Solid brick, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good | Good |
| WALL ENV EFF | Very Good | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | No thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.40 |
| CO2 EMISSIONS POTENTIAL | 1.50 |
| HEATING COST CURRENT | 3363.0000 |
| HEATING COST POTENTIAL | 1209.0000 |
| HOT WATER COST CURRENT | 1002.00 |
| HOT WATER COST POTENTIAL | 474.00 |
| LIGHTING COST CURRENT | 387.00 |
| LIGHTING COST POTENTIAL | 216.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 7318 |
| WATER HEATING DEMAND | 2178 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1984-1991 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01003447 (City Centre East) |
| ENERGY CONSUMPTION POTENTIAL | 264.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2601 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 8 |
| CONSTITUENCY | 00QSMK |
| CONSTITUENCY LABEL | Anderston/City |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010261 (City Centre East - 03) |
| CREATED AT | 24/06/2016 19:29:25 |
| REPORT REFERENCE NUMBER | 9300-4346-0229-0121-1663 |
| Source file | Q2 2016.csv |
| Address display | FLAT 0/2 , 39 ST MUNGO AVENUE , GLASGOW |
| Nation | scotland |