Energy Performance Certificate
31 HURKUR CRESCENT , EYEMOUTH, TD14 5AP
Energy rating
Current: 59 D | Potential: 76 C
Environmental impact (CO₂)
Current: 52
| Potential: 75
| Field | Value |
|---|---|
| Id | 4091693 |
| BUILDING REFERENCE NUMBER | 1000326199 |
| OSG REFERENCE NUMBER | 116014476 |
| ADDRESS1 | 31 HURKUR CRESCENT |
| ADDRESS2 | — |
| ADDRESS3 | EYEMOUTH |
| POSTCODE | TD14 5AP |
| INSPECTION DATE | 2016-06-02 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-02 |
| ENERGY CONSUMPTION CURRENT | 346.00 |
| TOTAL FLOOR AREA | 79 |
| 3 YR ENERGY COST CURRENT | 3270.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1401.0000 |
| CURRENT ENERGY EFFICIENCY | 59 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 76 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 52 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 75 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 61.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 117; Energy Rating after improvement: D 63; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 19; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 58; Green Deal Eligible: N | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 330; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 57% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.80 |
| CO2 EMISSIONS POTENTIAL | 2.30 |
| HEATING COST CURRENT | 1818.0000 |
| HEATING COST POTENTIAL | 1341.0000 |
| HOT WATER COST CURRENT | 1215.00 |
| HOT WATER COST POTENTIAL | 363.00 |
| LIGHTING COST CURRENT | 237.00 |
| LIGHTING COST POTENTIAL | 165.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 6806 |
| WATER HEATING DEMAND | 5152 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1930-1949 |
| FLOOR HEIGHT | 2.47 |
| DATA ZONE | S01005486 (Eyemouth) |
| ENERGY CONSUMPTION POTENTIAL | 181.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 57.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Scottish Borders |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QEMG |
| CONSTITUENCY LABEL | East Berwickshire |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01012316 (Eyemouth - Central) |
| CREATED AT | 02/06/2016 20:49:13 |
| REPORT REFERENCE NUMBER | 9300-3221-0629-7009-1663 |
| Source file | Q2 2016.csv |
| Address display | 31 HURKUR CRESCENT , EYEMOUTH |
| Nation | scotland |