Energy Performance Certificate

456 LEYLAND ROAD , BATHGATE, EH48 2UQ

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 86 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 86 Potential: 86
Field Value
Id 4337626
BUILDING REFERENCE NUMBER 1001493227
OSG REFERENCE NUMBER 135024588
ADDRESS1 456 LEYLAND ROAD
ADDRESS2
ADDRESS3 BATHGATE
POSTCODE EH48 2UQ
INSPECTION DATE 2023-05-17
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2023-05-17
ENERGY CONSUMPTION CURRENT 116.00
TOTAL FLOOR AREA 60
3 YR ENERGY COST CURRENT 2148.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 82
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 82
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 86
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 86
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 20.00
IMPROVEMENTS
WALL DESCRIPTION Cavity wall, as built, insulated (assumed) | Solid brick, as built, insulated (assumed)
WALL ENERGY EFF Very Good | Very Good
WALL ENV EFF Very Good | Very Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.20
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 1167.0000
HEATING COST POTENTIAL 1167.0000
HOT WATER COST CURRENT 651.00
HOT WATER COST POTENTIAL 651.00
LIGHTING COST CURRENT 330.00
LIGHTING COST POTENTIAL 330.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 1824
WATER HEATING DEMAND 1852
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 2008 onwards
FLOOR HEIGHT 2.33
DATA ZONE S01006364 (Blackburn)
ENERGY CONSUMPTION POTENTIAL 116.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL West Lothian
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 9.84
CONSTITUENCY 00RHMH
CONSTITUENCY LABEL Bathgate
WIND TURBINE COUNT 0
BUILT FORM Enclosed End-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01013401 (Bathgate, Wester Inch and Inchcross - 02)
CREATED AT 17/05/2023 13:03:19
REPORT REFERENCE NUMBER 9237-1014-2205-2137-9204
Source file Q2 2023.csv
Address display 456 LEYLAND ROAD , BATHGATE
Nation scotland