Energy Performance Certificate
36 TITWOOD ROAD , GLASGOW, G41 2DG
Energy rating
Current: 62 D | Potential: 84 B
Environmental impact (CO₂)
Current: 55
| Potential: 82
| Field | Value |
|---|---|
| Id | 5117499 |
| BUILDING REFERENCE NUMBER | 1000278275 |
| OSG REFERENCE NUMBER | 906700311062 |
| ADDRESS1 | 36 TITWOOD ROAD |
| ADDRESS2 | — |
| ADDRESS3 | GLASGOW |
| POSTCODE | G41 2DG |
| INSPECTION DATE | 2024-04-19 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2024-11-29 |
| ENERGY CONSUMPTION CURRENT | 288.00 |
| TOTAL FLOOR AREA | 86 |
| 3 YR ENERGY COST CURRENT | 4116.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1374.0000 |
| CURRENT ENERGY EFFICIENCY | 62 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 84 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 55 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 82 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 51.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 47; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 409; Energy Rating after improvement: B 84; Environmental Rating after improvement: B 82; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 68; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 40; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 43; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 73; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 64; Green Deal Eligible: Y | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 69; Energy Rating after improvement: C 71; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 117; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) | Sandstone or limestone, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Very Poor |
| WALL ENV EFF | Poor | Very Poor |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Partial double glazing |
| WINDOWS ENERGY EFF | Poor |
| WINDOWS ENV EFF | Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.40 |
| CO2 EMISSIONS POTENTIAL | 2.60 |
| HEATING COST CURRENT | 2871.0000 |
| HEATING COST POTENTIAL | 2106.0000 |
| HOT WATER COST CURRENT | 972.00 |
| HOT WATER COST POTENTIAL | 363.00 |
| LIGHTING COST CURRENT | 273.00 |
| LIGHTING COST POTENTIAL | 273.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 11151 |
| WATER HEATING DEMAND | 4381 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -1640 |
| IMPACT SOLID WALL INSULATION | -601 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1930-1949 |
| FLOOR HEIGHT | 2.73 |
| DATA ZONE | S01003177 (Strathbungo) |
| ENERGY CONSUMPTION POTENTIAL | 119.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 4 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QSMF |
| CONSTITUENCY LABEL | Pollokshields |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009911 (Strathbungo - 07) |
| CREATED AT | 29/11/2024 05:27:13 |
| REPORT REFERENCE NUMBER | 9215-1002-7204-2484-7204 |
| Source file | Q4 2024.csv |
| Address display | 36 TITWOOD ROAD , GLASGOW |
| Nation | scotland |