Energy Performance Certificate
70 YARROW COURT , KIRKHILL , PENICUIK, EH26 8HE
Energy rating
Current: 72 C | Potential: 85 B
Environmental impact (CO₂)
Current: 70
| Potential: 84
| Field | Value |
|---|---|
| Id | 4980090 |
| BUILDING REFERENCE NUMBER | 1000401766 |
| OSG REFERENCE NUMBER | 120005566 |
| ADDRESS1 | 70 YARROW COURT |
| ADDRESS2 | KIRKHILL |
| ADDRESS3 | PENICUIK |
| POSTCODE | EH26 8HE |
| INSPECTION DATE | 2020-10-05 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-10-06 |
| ENERGY CONSUMPTION CURRENT | 244.00 |
| TOTAL FLOOR AREA | 79 |
| 3 YR ENERGY COST CURRENT | 2289.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 234.0000 |
| CURRENT ENERGY EFFICIENCY | 72 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 70 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 43.00 |
| IMPROVEMENTS | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 29; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 307; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 48; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, as built, no insulation (assumed) |
| WALL ENERGY EFF | Very Poor |
| WALL ENV EFF | Very Poor |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.40 |
| CO2 EMISSIONS POTENTIAL | 1.30 |
| HEATING COST CURRENT | 1803.0000 |
| HEATING COST POTENTIAL | 1656.0000 |
| HOT WATER COST CURRENT | 291.00 |
| HOT WATER COST POTENTIAL | 204.00 |
| LIGHTING COST CURRENT | 195.00 |
| LIGHTING COST POTENTIAL | 195.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 10894 |
| WATER HEATING DEMAND | 2103 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.39 |
| DATA ZONE | S01004140 (Penicuik East) |
| ENERGY CONSUMPTION POTENTIAL | 149.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Midlothian |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QWMA |
| CONSTITUENCY LABEL | Penicuik |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01010945 (Penicuik East - 01) |
| CREATED AT | 06/10/2020 16:56:50 |
| REPORT REFERENCE NUMBER | 9170-2615-6000-2000-2425 |
| Source file | Q4 2020.csv |
| Address display | 70 YARROW COURT , KIRKHILL , PENICUIK |
| Nation | scotland |