Energy Performance Certificate
16 GLEN IOSAL , TOBERMORY , ISLE OF MULL, PA75 6PX
Energy rating
Current: 88 B | Potential: 97 A
Environmental impact (CO₂)
Current: 93
| Potential: 94
| Field | Value |
|---|---|
| Id | 5170010 |
| BUILDING REFERENCE NUMBER | 1001343541 |
| OSG REFERENCE NUMBER | 125035256 |
| ADDRESS1 | 16 GLEN IOSAL |
| ADDRESS2 | TOBERMORY |
| ADDRESS3 | ISLE OF MULL |
| POSTCODE | PA75 6PX |
| INSPECTION DATE | 2025-10-29 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-12-23 |
| ENERGY CONSUMPTION CURRENT | 191.00 |
| TOTAL FLOOR AREA | 33 |
| 3 YR ENERGY COST CURRENT | 3651.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 723.0000 |
| CURRENT ENERGY EFFICIENCY | 88 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 97 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 93 |
| CURRENT ENVIRONMENTAL RATING | A |
| ENVIRONMENT IMPACT POTENTIAL | 94 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 16.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £20 - £40; Typical Saving: 36; Energy Rating after improvement: B 90; Environmental Rating after improvement: A 93; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,600 - £3,200; Typical Saving: 93; Energy Rating after improvement: A 96; Environmental Rating after improvement: A 93; Green Deal Eligible: N | Description: Heat recovery system for mixer showers; Indicative Cost: £600 - £1,500; Typical Saving: 45; Energy Rating after improvement: A 97; Environmental Rating after improvement: A 94; Green Deal Eligible: N | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | — |
| WINDOWS ENERGY EFF | — |
| WINDOWS ENV EFF | — |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Automatic charge control | Controls for high heat retention storage heaters |
| MAINHEATC ENERGY EFF | Average | Good |
| MAINHEATC ENV EFF | Average | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Below average lighting efficiency |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 0.50 |
| CO2 EMISSIONS POTENTIAL | 0.00 |
| HEATING COST CURRENT | 2127.0000 |
| HEATING COST POTENTIAL | 2097.0000 |
| HOT WATER COST CURRENT | 1419.00 |
| HOT WATER COST POTENTIAL | 726.00 |
| LIGHTING COST CURRENT | 105.00 |
| LIGHTING COST POTENTIAL | 105.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 3647.13 |
| WATER HEATING DEMAND | 1799.91 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1984-1991 |
| FLOOR HEIGHT | — |
| DATA ZONE | S01000832 (Mull, Iona, Coll and Tiree) |
| ENERGY CONSUMPTION POTENTIAL | 180.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 0 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 1 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 1 |
| LOCAL AUTHORITY LABEL | Argyll and Bute |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | — |
| MAIN FUEL | — |
| MAIN HEATING CONTROLS | — |
| MECHANICAL VENTILATION | mechanical, extract only |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | — |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QDMD |
| CONSTITUENCY LABEL | Oban South and the Isles |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007286 (Mull, Iona, Coll and Tiree - 03) |
| CREATED AT | 23/12/2025 11:16:04 |
| REPORT REFERENCE NUMBER | 9150-2131-4100-2425-6311 |
| Source file | Q4 2025.csv |
| Address display | 16 GLEN IOSAL , TOBERMORY , ISLE OF MULL |
| Nation | scotland |