Energy Performance Certificate
16A FLEMING GARDENS NORTH , DUNDEE, DD3 7LP
Energy rating
Current: 63 D | Potential: 77 C
Environmental impact (CO₂)
Current: 61
| Potential: 80
| Field | Value |
|---|---|
| Id | 5014974 |
| BUILDING REFERENCE NUMBER | 1000631120 |
| OSG REFERENCE NUMBER | 9059048405 |
| ADDRESS1 | 16A FLEMING GARDENS NORTH |
| ADDRESS2 | — |
| ADDRESS3 | DUNDEE |
| POSTCODE | DD3 7LP |
| INSPECTION DATE | 2021-11-02 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2021-11-28 |
| ENERGY CONSUMPTION CURRENT | 348.00 |
| TOTAL FLOOR AREA | 54 |
| 3 YR ENERGY COST CURRENT | 2208.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 915.0000 |
| CURRENT ENERGY EFFICIENCY | 63 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 61 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 61.00 |
| IMPROVEMENTS | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 169; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 92; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £35; Typical Saving: 44; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 80; Green Deal Eligible: N | |
| WALL DESCRIPTION | Solid brick, as built, no insulation (assumed) | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Poor | Average |
| WALL ENV EFF | Poor | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.30 |
| CO2 EMISSIONS POTENTIAL | 1.60 |
| HEATING COST CURRENT | 1674.0000 |
| HEATING COST POTENTIAL | 909.0000 |
| HOT WATER COST CURRENT | 234.00 |
| HOT WATER COST POTENTIAL | 234.00 |
| LIGHTING COST CURRENT | 300.00 |
| LIGHTING COST POTENTIAL | 150.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 9670 |
| WATER HEATING DEMAND | 1868 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -3841 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1919-1929 |
| FLOOR HEIGHT | 2.5 |
| DATA ZONE | S01001192 (The Glens) |
| ENERGY CONSUMPTION POTENTIAL | 178.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 4 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Dundee City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | 6.5 |
| CONSTITUENCY | 00QJMD |
| CONSTITUENCY LABEL | Coldside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007723 (The Glens - 04) |
| CREATED AT | 28/11/2021 18:10:20 |
| REPORT REFERENCE NUMBER | 9110-2012-2090-2309-4635 |
| Source file | Q4 2021.csv |
| Address display | 16A FLEMING GARDENS NORTH , DUNDEE |
| Nation | scotland |