Energy Performance Certificate

2F3 , 42 HAWTHORNVALE , EDINBURGH, EH6 4JW

EPC Report

Energy rating

Current: 77 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 78 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 86 Potential: 86
Field Value
Id 4090032
BUILDING REFERENCE NUMBER 1000191779
OSG REFERENCE NUMBER 906337216
ADDRESS1 2F3
ADDRESS2 42 HAWTHORNVALE
ADDRESS3 EDINBURGH
POSTCODE EH6 4JW
INSPECTION DATE 2016-06-16
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-23
ENERGY CONSUMPTION CURRENT 155.00
TOTAL FLOOR AREA 79
3 YR ENERGY COST CURRENT 1689.0000
3 YR ENERGY SAVINGS POTENTIAL 480.0000
CURRENT ENERGY EFFICIENCY 77
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 83
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 78
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 86
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 27.00
IMPROVEMENTS Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 129; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 31; Energy Rating after improvement: B 83; Environmental Rating after improvement: B 86; Green Deal Eligible: N |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Very Poor | Poor
WALL ENV EFF Very Poor | Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.20
CO2 EMISSIONS POTENTIAL 0.80
HEATING COST CURRENT 1134.0000
HEATING COST POTENTIAL 762.0000
HOT WATER COST CURRENT 279.00
HOT WATER COST POTENTIAL 282.00
LIGHTING COST CURRENT 276.00
LIGHTING COST POTENTIAL 165.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 4797
WATER HEATING DEMAND 1923
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -2418
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 2.9
DATA ZONE S01002326 (North Leith and Newhaven)
ENERGY CONSUMPTION POTENTIAL 102.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 2
LOW ENERGY LIGHTING 33.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 6.35
CONSTITUENCY 00QPMN
CONSTITUENCY LABEL Leith
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008773 (North Leith and Newhaven - 02)
CREATED AT 23/06/2016 14:41:42
REPORT REFERENCE NUMBER 9100-3967-0129-4097-1663
Source file Q2 2016.csv
Address display 2F3 , 42 HAWTHORNVALE , EDINBURGH
Nation scotland