Energy Performance Certificate
FLAT 1/1 , 12 CAMBUSDOON ROAD , GLASGOW, G33 5QG
Energy rating
Current: 70 C | Potential: 80 C
Environmental impact (CO₂)
Current: 62
| Potential: 67
| Field | Value |
|---|---|
| Id | 4247599 |
| BUILDING REFERENCE NUMBER | 1001174392 |
| OSG REFERENCE NUMBER | 906700144049 |
| ADDRESS1 | FLAT 1/1 |
| ADDRESS2 | 12 CAMBUSDOON ROAD |
| ADDRESS3 | GLASGOW |
| POSTCODE | G33 5QG |
| INSPECTION DATE | 2021-06-16 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2021-06-16 |
| ENERGY CONSUMPTION CURRENT | 307.00 |
| TOTAL FLOOR AREA | 65 |
| 3 YR ENERGY COST CURRENT | 2586.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 882.0000 |
| CURRENT ENERGY EFFICIENCY | 70 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 80 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 62 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 67 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 52.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £45; Typical Saving: 45; Energy Rating after improvement: C 73; Environmental Rating after improvement: D 66; Green Deal Eligible: N | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 195; Energy Rating after improvement: C 80; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 56; Energy Rating after improvement: C 72; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, partial insulation (assumed) | Cavity wall, filled cavity and external insulation |
| WALL ENERGY EFF | Average | Very Good |
| WALL ENV EFF | Average | Very Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Automatic charge control |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.40 |
| CO2 EMISSIONS POTENTIAL | 0.60 |
| HEATING COST CURRENT | 1323.0000 |
| HEATING COST POTENTIAL | 972.0000 |
| HOT WATER COST CURRENT | 888.00 |
| HOT WATER COST POTENTIAL | 543.00 |
| LIGHTING COST CURRENT | 375.00 |
| LIGHTING COST POTENTIAL | 189.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4104 |
| WATER HEATING DEMAND | 1774 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -517 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.44 |
| DATA ZONE | S01003483 (Craigend and Ruchazie) |
| ENERGY CONSUMPTION POTENTIAL | 260.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2402 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 8.9 |
| CONSTITUENCY | 00QSMX |
| CONSTITUENCY LABEL | North East |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010170 (Craigend and Ruchazie - 06) |
| CREATED AT | 16/06/2021 13:17:18 |
| REPORT REFERENCE NUMBER | 9062-1011-9206-3549-7204 |
| Source file | Q2 2021.csv |
| Address display | FLAT 1/1 , 12 CAMBUSDOON ROAD , GLASGOW |
| Nation | scotland |