Energy Performance Certificate
45 QUEEN'S ROAD , EYEMOUTH, TD14 5DR
Energy rating
Current: 70 C | Potential: 85 B
Environmental impact (CO₂)
Current: 68
| Potential: 84
| Field | Value |
|---|---|
| Id | 4098119 |
| BUILDING REFERENCE NUMBER | 1001041309 |
| OSG REFERENCE NUMBER | 116026189 |
| ADDRESS1 | 45 QUEEN'S ROAD |
| ADDRESS2 | — |
| ADDRESS3 | EYEMOUTH |
| POSTCODE | TD14 5DR |
| INSPECTION DATE | 2016-06-13 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-16 |
| ENERGY CONSUMPTION CURRENT | 242.00 |
| TOTAL FLOOR AREA | 72 |
| 3 YR ENERGY COST CURRENT | 2223.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 297.0000 |
| CURRENT ENERGY EFFICIENCY | 70 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 68 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 43.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 279; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 21; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 71; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 33; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 45; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.10 |
| CO2 EMISSIONS POTENTIAL | 1.40 |
| HEATING COST CURRENT | 1701.0000 |
| HEATING COST POTENTIAL | 1575.0000 |
| HOT WATER COST CURRENT | 303.00 |
| HOT WATER COST POTENTIAL | 204.00 |
| LIGHTING COST CURRENT | 219.00 |
| LIGHTING COST POTENTIAL | 147.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 9308 |
| WATER HEATING DEMAND | 2138 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01005485 (Eyemouth) |
| ENERGY CONSUMPTION POTENTIAL | 127.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 50.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Scottish Borders |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QEMG |
| CONSTITUENCY LABEL | East Berwickshire |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01012314 (Eyemouth - Gunsgreen) |
| CREATED AT | 16/06/2016 16:03:55 |
| REPORT REFERENCE NUMBER | 9000-6473-0129-2190-1663 |
| Source file | Q2 2016.csv |
| Address display | 45 QUEEN'S ROAD , EYEMOUTH |
| Nation | scotland |