Energy Performance Certificate

3 DRYSDALE GAIT , FOUNTAINBRIDGE , EDINBURGH, EH3 8FZ

EPC Report

Energy rating

Current: 81 B | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 87 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 87 Potential: 87
Field Value
Id 4035851
BUILDING REFERENCE NUMBER 1236551428
OSG REFERENCE NUMBER 10096519161
ADDRESS1 3 DRYSDALE GAIT
ADDRESS2 FOUNTAINBRIDGE
ADDRESS3 EDINBURGH
POSTCODE EH3 8FZ
INSPECTION DATE 2025-02-26
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2025-02-26
ENERGY CONSUMPTION CURRENT 104.00
TOTAL FLOOR AREA 59
3 YR ENERGY COST CURRENT 1494.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 81
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 81
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 87
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 87
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 18.00
IMPROVEMENTS
WALL DESCRIPTION Average thermal transmittance 0.17 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Average thermal transmittance 0.13 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 4.1 m³/h.m² (as tested)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 1.10
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 939.0000
HEATING COST POTENTIAL 939.0000
HOT WATER COST CURRENT 354.00
HOT WATER COST POTENTIAL 354.00
LIGHTING COST CURRENT 201.00
LIGHTING COST POTENTIAL 201.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES Description: Community combined heat and power |
SPACE HEATING DEMAND 2431
WATER HEATING DEMAND 1611
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT 2.48
DATA ZONE
ENERGY CONSUMPTION POTENTIAL 104.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL ground floor
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL
MAINS GAS FLAG
MAIN HEATING CATEGORY community heating system
MAIN FUEL
MAIN HEATING CONTROLS 2306
MECHANICAL VENTILATION
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
TENURE unknown
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY
CONSTITUENCY LABEL
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011
CREATED AT 26/02/2025 13:53:51
REPORT REFERENCE NUMBER 8502-8564-3132-1622-1253
Source file Q1 2025.csv
Address display 3 DRYSDALE GAIT , FOUNTAINBRIDGE , EDINBURGH
Nation scotland