Energy Performance Certificate
FLAT 2/2 , 67 CLOSEBURN STREET , GLASGOW, G22 5LB
Energy rating
Current: 76 C | Potential: 78 C
Environmental impact (CO₂)
Current: 78
| Potential: 81
| Field | Value |
|---|---|
| Id | 5094443 |
| BUILDING REFERENCE NUMBER | 1001456188 |
| OSG REFERENCE NUMBER | 906700024923 |
| ADDRESS1 | FLAT 2/2 |
| ADDRESS2 | 67 CLOSEBURN STREET |
| ADDRESS3 | GLASGOW |
| POSTCODE | G22 5LB |
| INSPECTION DATE | 2023-11-01 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-11-02 |
| ENERGY CONSUMPTION CURRENT | 177.00 |
| TOTAL FLOOR AREA | 53 |
| 3 YR ENERGY COST CURRENT | 2784.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 345.0000 |
| CURRENT ENERGY EFFICIENCY | 76 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 78 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 78 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 81 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 31.00 |
| IMPROVEMENTS | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 66; Energy Rating after improvement: C 78; Environmental Rating after improvement: B 81; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 48; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity and external insulation | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Very Good | Average |
| WALL ENV EFF | Very Good | Average |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.60 |
| CO2 EMISSIONS POTENTIAL | 0.20 |
| HEATING COST CURRENT | 1794.0000 |
| HEATING COST POTENTIAL | 1527.0000 |
| HOT WATER COST CURRENT | 711.00 |
| HOT WATER COST POTENTIAL | 633.00 |
| LIGHTING COST CURRENT | 279.00 |
| LIGHTING COST POTENTIAL | 279.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3416 |
| WATER HEATING DEMAND | 1743 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -382 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.54 |
| DATA ZONE | S01003582 (Possil Park) |
| ENERGY CONSUMPTION POTENTIAL | 151.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 5 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 5.9 |
| CONSTITUENCY | 00QSMR |
| CONSTITUENCY LABEL | Canal |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010323 (Possil Park - 01) |
| CREATED AT | 02/11/2023 10:20:02 |
| REPORT REFERENCE NUMBER | 8317-8529-1109-0689-4206 |
| Source file | Q4 2023.csv |
| Address display | FLAT 2/2 , 67 CLOSEBURN STREET , GLASGOW |