Energy Performance Certificate

35 WEST BONNINGTON DRIVE , WILKIESTON , KIRKNEWTON, EH27 8DP

EPC Report

Energy rating

Current: 86 B | Potential: 97 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 97 A Potential: 97 A

Environmental impact (CO₂)

Current: 88 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 97 Potential: 97
Field Value
Id 5110968
BUILDING REFERENCE NUMBER 1236289778
OSG REFERENCE NUMBER 135053803
ADDRESS1 35 WEST BONNINGTON DRIVE
ADDRESS2 WILKIESTON
ADDRESS3 KIRKNEWTON
POSTCODE EH27 8DP
INSPECTION DATE 2023-12-05
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2023-12-05
ENERGY CONSUMPTION CURRENT 86.00
TOTAL FLOOR AREA 100
3 YR ENERGY COST CURRENT 3102.0000
3 YR ENERGY SAVINGS POTENTIAL 309.0000
CURRENT ENERGY EFFICIENCY 86
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 97
POTENTIAL ENERGY RATING A
ENVIRONMENT IMPACT CURRENT 88
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 97
POTENTIAL ENVIRONMENTAL RATING A
CO2 EMISS CURR PER FLOOR AREA 15.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 104; Energy Rating after improvement: B 88; Environmental Rating after improvement: B 89; Green Deal Eligible: N | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 604; Energy Rating after improvement: A 97; Environmental Rating after improvement: A 97; Green Deal Eligible: N |
WALL DESCRIPTION Average thermal transmittance 0.22 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 5.0 m³/h.m² (assumed)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 1.50
CO2 EMISSIONS POTENTIAL 1.00
HEATING COST CURRENT 1695.0000
HEATING COST POTENTIAL 1698.0000
HOT WATER COST CURRENT 906.00
HOT WATER COST POTENTIAL 594.00
LIGHTING COST CURRENT 501.00
LIGHTING COST POTENTIAL 501.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES Description: Air source heat pump |
SPACE HEATING DEMAND 4347
WATER HEATING DEMAND 2300
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT 2.7
DATA ZONE
ENERGY CONSUMPTION POTENTIAL 27.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL
MAINS GAS FLAG
MAIN HEATING CATEGORY heat pump with radiators or underfloor heating
MAIN FUEL Electricity: electricity, unspecified tariff
MAIN HEATING CONTROLS 2207
MECHANICAL VENTILATION
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
TENURE unknown
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY
CONSTITUENCY LABEL
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE House
DATA ZONE 2011
CREATED AT 05/12/2023 08:29:49
REPORT REFERENCE NUMBER 8317-7832-7639-2925-2202
Source file Q4 2023.csv
Address display 35 WEST BONNINGTON DRIVE , WILKIESTON , KIRKNEWTON
Nation scotland