Energy Performance Certificate
28 College Way , Gullane, EH31 2BX
Energy rating
Current: 87 B | Potential: 88 B
Environmental impact (CO₂)
Current: 89
| Potential: 90
| Field | Value |
|---|---|
| Id | 4754664 |
| BUILDING REFERENCE NUMBER | 1235514458 |
| OSG REFERENCE NUMBER | — |
| ADDRESS1 | 28 College Way |
| ADDRESS2 | — |
| ADDRESS3 | Gullane |
| POSTCODE | EH31 2BX |
| INSPECTION DATE | 2023-06-30 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-07-02 |
| ENERGY CONSUMPTION CURRENT | 77.00 |
| TOTAL FLOOR AREA | 161 |
| 3 YR ENERGY COST CURRENT | 7530.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 387.0000 |
| CURRENT ENERGY EFFICIENCY | 87 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 88 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 89 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 90 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 13.00 |
| IMPROVEMENTS | Description: Heat recovery system for mixer showers; Indicative Cost: £585 - £725; Typical Saving: 129; Energy Rating after improvement: B 88; Environmental Rating after improvement: B 90; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Pitched, insulated (assumed) | Roof room(s), insulated |
| ROOF ENERGY EFF | Good | Very Good |
| ROOF ENV EFF | Good | Very Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Air source heat pump, radiators, electric | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Very Good | Good |
| MAINHEAT ENV EFF | Very Good | Good |
| MAINHEATCONT DESCRIPTION | Programmer and room thermostat | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Average | Good |
| MAINHEATC ENV EFF | Average | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.20 |
| CO2 EMISSIONS POTENTIAL | 0.20 |
| HEATING COST CURRENT | 4119.0000 |
| HEATING COST POTENTIAL | 4119.0000 |
| HOT WATER COST CURRENT | 2790.00 |
| HOT WATER COST POTENTIAL | 2403.00 |
| LIGHTING COST CURRENT | 621.00 |
| LIGHTING COST POTENTIAL | 621.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Air source heat pump | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 11229 |
| WATER HEATING DEMAND | 2523 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | — |
| ENERGY CONSUMPTION POTENTIAL | 70.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 22 |
| LOW ENERGY FIXED LIGHT COUNT | 22 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 7 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 7 |
| LOCAL AUTHORITY LABEL | — |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | heat pump with radiators or underfloor heating |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2204 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Peak Power: 4.07; Orientation: South West; Pitch: 45 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | — |
| CONSTITUENCY LABEL | — |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01008265 (IZ17 - 04) |
| CREATED AT | 02/07/2023 23:44:37 |
| REPORT REFERENCE NUMBER | 8317-5126-4530-2440-5276 |
| Source file | Q3 2023.csv |
| Address display | 28 College Way , Gullane |
| Nation | scotland |