Energy Performance Certificate
25 PEGASUS AVENUE , CARLUKE, ML8 5TN
Energy rating
Current: 75 C | Potential: 81 B
Environmental impact (CO₂)
Current: 50
| Potential: 61
| Field | Value |
|---|---|
| Id | 4327896 |
| BUILDING REFERENCE NUMBER | 1000848338 |
| OSG REFERENCE NUMBER | 484110403 |
| ADDRESS1 | 25 PEGASUS AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | CARLUKE |
| POSTCODE | ML8 5TN |
| INSPECTION DATE | 2023-05-23 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-05-30 |
| ENERGY CONSUMPTION CURRENT | 474.00 |
| TOTAL FLOOR AREA | 60 |
| 3 YR ENERGY COST CURRENT | 4953.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 747.0000 |
| CURRENT ENERGY EFFICIENCY | 75 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 81 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 50 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 61 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 80.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 129; Energy Rating after improvement: C 77; Environmental Rating after improvement: E 54; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 27; Energy Rating after improvement: C 78; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 93; Energy Rating after improvement: B 81; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, limited insulation (assumed) |
| ROOF ENERGY EFF | Poor |
| ROOF ENV EFF | Poor |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Controls for high heat retention storage heaters |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.80 |
| CO2 EMISSIONS POTENTIAL | 0.90 |
| HEATING COST CURRENT | 3684.0000 |
| HEATING COST POTENTIAL | 3366.0000 |
| HOT WATER COST CURRENT | 939.00 |
| HOT WATER COST POTENTIAL | 510.00 |
| LIGHTING COST CURRENT | 330.00 |
| LIGHTING COST POTENTIAL | 330.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 8044 |
| WATER HEATING DEMAND | 2109 |
| IMPACT LOFT INSULATION | -771 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.34 |
| DATA ZONE | S01005766 (Carluke West) |
| ENERGY CONSUMPTION POTENTIAL | 379.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | South Lanarkshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2404 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 40%; Connection: connected to dwelling’s electricity meter; | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RFMA |
| CONSTITUENCY LABEL | Clydesdale West |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01012599 (Carluke West - 02) |
| CREATED AT | 30/05/2023 15:30:06 |
| REPORT REFERENCE NUMBER | 8317-3425-3000-0827-8222 |
| Source file | Q2 2023.csv |
| Address display | 25 PEGASUS AVENUE , CARLUKE |
| Nation | scotland |