Energy Performance Certificate
10 GADIEBURN DRIVE , INVERURIE, AB51 6BR
Energy rating
Current: 77 C | Potential: 84 B
Environmental impact (CO₂)
Current: 82
| Potential: 88
| Field | Value |
|---|---|
| Id | 4354284 |
| BUILDING REFERENCE NUMBER | 1235559028 |
| OSG REFERENCE NUMBER | 151178554 |
| ADDRESS1 | 10 GADIEBURN DRIVE |
| ADDRESS2 | — |
| ADDRESS3 | INVERURIE |
| POSTCODE | AB51 6BR |
| INSPECTION DATE | 2023-06-07 |
| TYPE OF ASSESSMENT | SAP, new dwelling |
| LODGEMENT DATE | 2023-06-07 |
| ENERGY CONSUMPTION CURRENT | 114.00 |
| TOTAL FLOOR AREA | 191 |
| 3 YR ENERGY COST CURRENT | 8127.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 519.0000 |
| CURRENT ENERGY EFFICIENCY | 77 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 84 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 82 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 88 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 19.00 |
| IMPROVEMENTS | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 174; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 83; Green Deal Eligible: N | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 578; Energy Rating after improvement: B 84; Environmental Rating after improvement: B 88; Green Deal Eligible: N | |
| WALL DESCRIPTION | Average thermal transmittance 0.19 W/m²K |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Average thermal transmittance 0.12 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.08 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | Description: High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Air source heat pump, radiators, electric |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | Air permeability 3.1 m³/h.m² (as tested) |
| AIR TIGHTNESS ENERGY EFF | Good |
| AIR TIGHTNESS ENV EFF | Good |
| CO2 EMISSIONS CURRENT | 3.70 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 6066.0000 |
| HEATING COST POTENTIAL | 6072.0000 |
| HOT WATER COST CURRENT | 1422.00 |
| HOT WATER COST POTENTIAL | 897.00 |
| LIGHTING COST CURRENT | 639.00 |
| LIGHTING COST POTENTIAL | 639.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Air source heat pump | |
| SPACE HEATING DEMAND | 14904 |
| WATER HEATING DEMAND | 2292 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.45 |
| DATA ZONE | — |
| ENERGY CONSUMPTION POTENTIAL | 81.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 22 |
| LOW ENERGY FIXED LIGHT COUNT | 22 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 0 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 0 |
| LOCAL AUTHORITY LABEL | — |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | heat pump with radiators or underfloor heating |
| MAIN FUEL | Electricity: electricity, unspecified tariff |
| MAIN HEATING CONTROLS | 2207 |
| MECHANICAL VENTILATION | — |
| ENERGY TARIFF | — |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| TENURE | owner-occupied |
| TRANSACTION TYPE | new dwelling |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | — |
| CONSTITUENCY LABEL | — |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01006913 (Durno-Chapel of Garioch - 05) |
| CREATED AT | 07/06/2023 14:32:07 |
| REPORT REFERENCE NUMBER | 8317-2536-0530-2983-5202 |
| Source file | Q2 2023.csv |
| Address display | 10 GADIEBURN DRIVE , INVERURIE |
| Nation | scotland |