Energy Performance Certificate
FLAT 15 , 33 WATER STREET , EDINBURGH, EH6 6SZ
Energy rating
Current: 69 C | Potential: 75 C
Environmental impact (CO₂)
Current: 72
| Potential: 77
| Field | Value |
|---|---|
| Id | 4114269 |
| BUILDING REFERENCE NUMBER | 1002371488 |
| OSG REFERENCE NUMBER | 906458656 |
| ADDRESS1 | FLAT 15 |
| ADDRESS2 | 33 WATER STREET |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH6 6SZ |
| INSPECTION DATE | 2016-06-07 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-07 |
| ENERGY CONSUMPTION CURRENT | 187.00 |
| TOTAL FLOOR AREA | 100 |
| 3 YR ENERGY COST CURRENT | 2802.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 456.0000 |
| CURRENT ENERGY EFFICIENCY | 69 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 75 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 72 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 77 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 32.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £35; Typical Saving: 43; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 74; Green Deal Eligible: N | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 78; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 76; Green Deal Eligible: Y | Description: Heat recovery system for mixer showers; Indicative Cost: £585 - £725; Typical Saving: 30; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.20 |
| CO2 EMISSIONS POTENTIAL | 0.60 |
| HEATING COST CURRENT | 681.0000 |
| HEATING COST POTENTIAL | 924.0000 |
| HOT WATER COST CURRENT | 1707.00 |
| HOT WATER COST POTENTIAL | 1215.00 |
| LIGHTING COST CURRENT | 414.00 |
| LIGHTING COST POTENTIAL | 207.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 1362 |
| WATER HEATING DEMAND | 3713 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 2003-2007 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01002288 (Leith Docks) |
| ENERGY CONSUMPTION POTENTIAL | 157.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 8.3 |
| CONSTITUENCY | 00QPMN |
| CONSTITUENCY LABEL | Leith |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008783 (The Shore and Constitution Street - 06) |
| CREATED AT | 07/06/2016 14:56:18 |
| REPORT REFERENCE NUMBER | 8300-6734-0129-7208-1663 |
| Source file | Q2 2016.csv |
| Address display | FLAT 15 , 33 WATER STREET , EDINBURGH |
| Nation | scotland |