Energy Performance Certificate

FLAT 1/1 , 118 GARTHLAND DRIVE , GLASGOW, G31 2SG

EPC Report

Energy rating

Current: 74 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 74 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 86 Potential: 86
Field Value
Id 4091461
BUILDING REFERENCE NUMBER 1000342638
OSG REFERENCE NUMBER 906700170632
ADDRESS1 FLAT 1/1
ADDRESS2 118 GARTHLAND DRIVE
ADDRESS3 GLASGOW
POSTCODE G31 2SG
INSPECTION DATE 2016-06-17
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-20
ENERGY CONSUMPTION CURRENT 199.00
TOTAL FLOOR AREA 59
3 YR ENERGY COST CURRENT 1587.0000
3 YR ENERGY SAVINGS POTENTIAL 561.0000
CURRENT ENERGY EFFICIENCY 74
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 82
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 74
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 86
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 35.00
IMPROVEMENTS Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 57; Energy Rating after improvement: C 79; Environmental Rating after improvement: B 82; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 69; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 78; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 61; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 86; Green Deal Eligible: Y |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Average
WALL ENV EFF Poor | Average
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.10
CO2 EMISSIONS POTENTIAL 1.00
HEATING COST CURRENT 1104.0000
HEATING COST POTENTIAL 597.0000
HOT WATER COST CURRENT 342.00
HOT WATER COST POTENTIAL 285.00
LIGHTING COST CURRENT 141.00
LIGHTING COST POTENTIAL 144.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 4238
WATER HEATING DEMAND 1836
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -1192
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 3.2
DATA ZONE S01003385 (Dennistoun)
ENERGY CONSUMPTION POTENTIAL 109.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
LOW ENERGY LIGHTING 86.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 01
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Glasgow City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 8.2
CONSTITUENCY 00QSMT
CONSTITUENCY LABEL East Centre
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01010248 (Dennistoun - 01)
CREATED AT 20/06/2016 14:57:02
REPORT REFERENCE NUMBER 8300-5436-0229-6093-1663
Source file Q2 2016.csv
Address display FLAT 1/1 , 118 GARTHLAND DRIVE , GLASGOW
Nation scotland