Energy Performance Certificate
FLAT 3/2 , 52 CASTLEMILK DRIVE , GLASGOW, G45 9TP
Energy rating
Current: 76 C | Potential: 79 C
Environmental impact (CO₂)
Current: 77
| Potential: 80
| Field | Value |
|---|---|
| Id | 4100506 |
| BUILDING REFERENCE NUMBER | 1001143908 |
| OSG REFERENCE NUMBER | 906700251719 |
| ADDRESS1 | FLAT 3/2 |
| ADDRESS2 | 52 CASTLEMILK DRIVE |
| ADDRESS3 | GLASGOW |
| POSTCODE | G45 9TP |
| INSPECTION DATE | 2016-06-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-08 |
| ENERGY CONSUMPTION CURRENT | 169.00 |
| TOTAL FLOOR AREA | 68 |
| 3 YR ENERGY COST CURRENT | 1617.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 225.0000 |
| CURRENT ENERGY EFFICIENCY | 76 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 77 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 80 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 30.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 40; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 78; Green Deal Eligible: N | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 35; Energy Rating after improvement: C 79; Environmental Rating after improvement: C 80; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.00 |
| CO2 EMISSIONS POTENTIAL | 0.30 |
| HEATING COST CURRENT | 984.0000 |
| HEATING COST POTENTIAL | 942.0000 |
| HOT WATER COST CURRENT | 342.00 |
| HOT WATER COST POTENTIAL | 303.00 |
| LIGHTING COST CURRENT | 291.00 |
| LIGHTING COST POTENTIAL | 147.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 3879 |
| WATER HEATING DEMAND | 1977 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.6 |
| DATA ZONE | S01003052 (Castlemilk) |
| ENERGY CONSUMPTION POTENTIAL | 144.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 6 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | 5.5 |
| CONSTITUENCY | 00QSMA |
| CONSTITUENCY LABEL | Linn |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01009992 (Castlemilk - 07) |
| CREATED AT | 08/06/2016 14:48:12 |
| REPORT REFERENCE NUMBER | 8100-4489-0329-4100-1663 |
| Source file | Q2 2016.csv |
| Address display | FLAT 3/2 , 52 CASTLEMILK DRIVE , GLASGOW |
| Nation | scotland |