Energy Performance Certificate
44 GILMERTON DYKES TERRACE , EDINBURGH, EH17 8LU
Energy rating
Current: 70 C | Potential: 86 B
Environmental impact (CO₂)
Current: 68
| Potential: 85
| Field | Value |
|---|---|
| Id | 4473055 |
| BUILDING REFERENCE NUMBER | 1001042348 |
| OSG REFERENCE NUMBER | 906106564 |
| ADDRESS1 | 44 GILMERTON DYKES TERRACE |
| ADDRESS2 | — |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH17 8LU |
| INSPECTION DATE | 2016-06-15 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-08-03 |
| ENERGY CONSUMPTION CURRENT | 244.00 |
| TOTAL FLOOR AREA | 68 |
| 3 YR ENERGY COST CURRENT | 2109.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 321.0000 |
| CURRENT ENERGY EFFICIENCY | 70 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 86 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 68 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 85 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 43.00 |
| IMPROVEMENTS | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 27; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 45; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 33; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 258; Energy Rating after improvement: B 86; Environmental Rating after improvement: B 85; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Good | Very Poor |
| ROOF ENV EFF | Good | Very Poor |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.90 |
| CO2 EMISSIONS POTENTIAL | 1.40 |
| HEATING COST CURRENT | 1662.0000 |
| HEATING COST POTENTIAL | 1443.0000 |
| HOT WATER COST CURRENT | 309.00 |
| HOT WATER COST POTENTIAL | 207.00 |
| LIGHTING COST CURRENT | 138.00 |
| LIGHTING COST POTENTIAL | 138.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 8398 |
| WATER HEATING DEMAND | 2027 |
| IMPACT LOFT INSULATION | -558 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.24 |
| DATA ZONE | S01001817 (Hyvots and Gilmerton Dykes) |
| ENERGY CONSUMPTION POTENTIAL | 123.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QPMR |
| CONSTITUENCY LABEL | Liberton/Gilmerton |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01008560 (Hyvots and Gilmerton - 02) |
| CREATED AT | 03/08/2016 14:46:55 |
| REPORT REFERENCE NUMBER | 8000-6453-0229-7194-1663 |
| Source file | Q3 2016.csv |
| Address display | 44 GILMERTON DYKES TERRACE , EDINBURGH |
| Nation | scotland |