Energy Performance Certificate

3B QUEEN'S GARDENS , HUNTLY, AB54 8FQ

EPC Report

Energy rating

Current: 74 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 77 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 81 Potential: 81
Field Value
Id 4651908
BUILDING REFERENCE NUMBER 1001688477
OSG REFERENCE NUMBER 151050874
ADDRESS1 3B QUEEN'S GARDENS
ADDRESS2
ADDRESS3 HUNTLY
POSTCODE AB54 8FQ
INSPECTION DATE 2021-08-17
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2021-08-18
ENERGY CONSUMPTION CURRENT 255.00
TOTAL FLOOR AREA 34
3 YR ENERGY COST CURRENT 1194.0000
3 YR ENERGY SAVINGS POTENTIAL 132.0000
CURRENT ENERGY EFFICIENCY 74
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 76
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 77
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 81
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 45.00
IMPROVEMENTS Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 44; Energy Rating after improvement: C 76; Environmental Rating after improvement: B 81; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.50
CO2 EMISSIONS POTENTIAL 0.20
HEATING COST CURRENT 891.0000
HEATING COST POTENTIAL 759.0000
HOT WATER COST CURRENT 186.00
HOT WATER COST POTENTIAL 186.00
LIGHTING COST CURRENT 117.00
LIGHTING COST POTENTIAL 117.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 4117
WATER HEATING DEMAND 1474
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1984-1991
FLOOR HEIGHT 2.38
DATA ZONE S01000459 (Huntly)
ENERGY CONSUMPTION POTENTIAL 213.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
LOW ENERGY LIGHTING 83.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Aberdeenshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (social)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH 7.92
CONSTITUENCY 00QBMP
CONSTITUENCY LABEL Huntly, Strathbogie and Howe of Alford
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01007009 (Huntly - 02)
CREATED AT 18/08/2021 10:49:22
REPORT REFERENCE NUMBER 7819-7828-4100-0803-6296
Source file Q3 2021.csv
Address display 3B QUEEN'S GARDENS , HUNTLY
Nation scotland