Energy Performance Certificate
34A MOSSVALE STREET , PAISLEY, PA3 2LR
Energy rating
Current: 73 C | Potential: 77 C
Environmental impact (CO₂)
Current: 81
| Potential: 85
| Field | Value |
|---|---|
| Id | 4838460 |
| BUILDING REFERENCE NUMBER | 1001777472 |
| OSG REFERENCE NUMBER | 123063533 |
| ADDRESS1 | 34A MOSSVALE STREET |
| ADDRESS2 | — |
| ADDRESS3 | PAISLEY |
| POSTCODE | PA3 2LR |
| INSPECTION DATE | 2025-07-30 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-08-04 |
| ENERGY CONSUMPTION CURRENT | 138.00 |
| TOTAL FLOOR AREA | 72 |
| 3 YR ENERGY COST CURRENT | 2901.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 576.0000 |
| CURRENT ENERGY EFFICIENCY | 73 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 81 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 85 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 23.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £300 - £350; Typical Saving: 99; Energy Rating after improvement: C 76; Environmental Rating after improvement: B 84; Green Deal Eligible: N | Description: Replacement glazing units; Indicative Cost: £4,500 - £6,000; Typical Saving: 42; Energy Rating after improvement: C 77; Environmental Rating after improvement: B 85; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £5,000 - £10,000; Typical Saving: 50; Energy Rating after improvement: C 74; Environmental Rating after improvement: B 83; Green Deal Eligible: N | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | — |
| WINDOWS ENERGY EFF | — |
| WINDOWS ENV EFF | — |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Below average lighting efficiency |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.60 |
| CO2 EMISSIONS POTENTIAL | 0.30 |
| HEATING COST CURRENT | 1530.0000 |
| HEATING COST POTENTIAL | 1296.0000 |
| HOT WATER COST CURRENT | 876.00 |
| HOT WATER COST POTENTIAL | 876.00 |
| LIGHTING COST CURRENT | 495.00 |
| LIGHTING COST POTENTIAL | 153.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4866.32 |
| WATER HEATING DEMAND | 1857.52 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | — |
| DATA ZONE | S01005284 (Paisley North) |
| ENERGY CONSUMPTION POTENTIAL | 110.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 0 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Renfrewshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | — |
| MAIN FUEL | — |
| MAIN HEATING CONTROLS | — |
| MECHANICAL VENTILATION | — |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | none of the above |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RCMD |
| CONSTITUENCY LABEL | Paisley North West |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | — |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01012156 (Paisley North - 04) |
| CREATED AT | 04/08/2025 20:23:18 |
| REPORT REFERENCE NUMBER | 7602-1017-7203-4675-7204 |
| Source file | Q3 2025.csv |
| Address display | 34A MOSSVALE STREET , PAISLEY |
| Nation | scotland |