Energy Performance Certificate
63 DRUM ROAD , DUNFERMLINE, KY11 4NW
Energy rating
Current: 65 D | Potential: 85 B
Environmental impact (CO₂)
Current: 61
| Potential: 84
| Field | Value |
|---|---|
| Id | 4104644 |
| BUILDING REFERENCE NUMBER | 1001526327 |
| OSG REFERENCE NUMBER | 320116081 |
| ADDRESS1 | 63 DRUM ROAD |
| ADDRESS2 | — |
| ADDRESS3 | DUNFERMLINE |
| POSTCODE | KY11 4NW |
| INSPECTION DATE | 2016-06-30 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-30 |
| ENERGY CONSUMPTION CURRENT | 302.00 |
| TOTAL FLOOR AREA | 65 |
| 3 YR ENERGY COST CURRENT | 2457.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 618.0000 |
| CURRENT ENERGY EFFICIENCY | 65 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 61 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 53.00 |
| IMPROVEMENTS | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 114; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 35; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 27; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 255; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 31; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor |
| WALL ENV EFF | Poor |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Mostly double glazing |
| WINDOWS ENERGY EFF | Poor |
| WINDOWS ENV EFF | Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 78% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.50 |
| CO2 EMISSIONS POTENTIAL | 1.90 |
| HEATING COST CURRENT | 1983.0000 |
| HEATING COST POTENTIAL | 1455.0000 |
| HOT WATER COST CURRENT | 309.00 |
| HOT WATER COST POTENTIAL | 219.00 |
| LIGHTING COST CURRENT | 165.00 |
| LIGHTING COST POTENTIAL | 165.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 10538 |
| WATER HEATING DEMAND | 2124 |
| IMPACT LOFT INSULATION | -352 |
| IMPACT CAVITY WALL INSULATION | -2262 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.45 |
| DATA ZONE | S01002645 (Dunfermline Abbeyview South) |
| ENERGY CONSUMPTION POTENTIAL | 134.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 78.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Fife |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 83 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QRMD |
| CONSTITUENCY LABEL | Dunfermline South |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009344 (Abbeyview South East) |
| CREATED AT | 30/06/2016 13:57:21 |
| REPORT REFERENCE NUMBER | 7500-4203-0629-5172-1663 |
| Source file | Q2 2016.csv |
| Address display | 63 DRUM ROAD , DUNFERMLINE |
| Nation | scotland |