Energy Performance Certificate
20 EASTERTON DRIVE , COWIE , STIRLING, FK7 7AF
Energy rating
Current: 83 B | Potential: 86 B
Environmental impact (CO₂)
Current: 82
| Potential: 86
| Field | Value |
|---|---|
| Id | 4102993 |
| BUILDING REFERENCE NUMBER | 1001462047 |
| OSG REFERENCE NUMBER | 122034451 |
| ADDRESS1 | 20 EASTERTON DRIVE |
| ADDRESS2 | COWIE |
| ADDRESS3 | STIRLING |
| POSTCODE | FK7 7AF |
| INSPECTION DATE | 2016-06-11 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-11 |
| ENERGY CONSUMPTION CURRENT | 128.00 |
| TOTAL FLOOR AREA | 93 |
| 3 YR ENERGY COST CURRENT | 2301.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 285.0000 |
| CURRENT ENERGY EFFICIENCY | 83 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 86 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 82 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 86 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 23.00 |
| IMPROVEMENTS | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 62; Energy Rating after improvement: B 85; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 33; Energy Rating after improvement: B 86; Environmental Rating after improvement: B 86; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, with external insulation |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.10 |
| CO2 EMISSIONS POTENTIAL | 0.40 |
| HEATING COST CURRENT | 1806.0000 |
| HEATING COST POTENTIAL | 1620.0000 |
| HOT WATER COST CURRENT | 315.00 |
| HOT WATER COST POTENTIAL | 216.00 |
| LIGHTING COST CURRENT | 180.00 |
| LIGHTING COST POTENTIAL | 180.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 8210 |
| WATER HEATING DEMAND | 2146 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.54 |
| DATA ZONE | S01006082 (Sauchenford) |
| ENERGY CONSUMPTION POTENTIAL | 100.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Stirling |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Peak Power: 2.29; Orientation: South East; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RGMG |
| CONSTITUENCY LABEL | Bannockburn |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01013030 (Cowie - 02) |
| CREATED AT | 11/06/2016 16:06:27 |
| REPORT REFERENCE NUMBER | 7400-5690-0229-2194-1663 |
| Source file | Q2 2016.csv |
| Address display | 20 EASTERTON DRIVE , COWIE , STIRLING |
| Nation | scotland |