Energy Performance Certificate
142A STRATHMORE DRIVE , CORNTON , STIRLING, FK9 5DS
Energy rating
Current: 87 B | Potential: 91 B
Environmental impact (CO₂)
Current: 86
| Potential: 92
| Field | Value |
|---|---|
| Id | 4113103 |
| BUILDING REFERENCE NUMBER | 1002494757 |
| OSG REFERENCE NUMBER | 122023466 |
| ADDRESS1 | 142A STRATHMORE DRIVE |
| ADDRESS2 | CORNTON |
| ADDRESS3 | STIRLING |
| POSTCODE | FK9 5DS |
| INSPECTION DATE | 2016-06-29 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-29 |
| ENERGY CONSUMPTION CURRENT | 116.00 |
| TOTAL FLOOR AREA | 69 |
| 3 YR ENERGY COST CURRENT | 1917.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 309.0000 |
| CURRENT ENERGY EFFICIENCY | 87 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 91 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 86 |
| CURRENT ENVIRONMENTAL RATING | B |
| ENVIRONMENT IMPACT POTENTIAL | 92 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 21.00 |
| IMPROVEMENTS | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 103; Energy Rating after improvement: B 91; Environmental Rating after improvement: A 92; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 1.40 |
| CO2 EMISSIONS POTENTIAL | 0.40 |
| HEATING COST CURRENT | 1482.0000 |
| HEATING COST POTENTIAL | 1173.0000 |
| HOT WATER COST CURRENT | 288.00 |
| HOT WATER COST POTENTIAL | 288.00 |
| LIGHTING COST CURRENT | 147.00 |
| LIGHTING COST POTENTIAL | 147.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Solar photovoltaics | |
| SPACE HEATING DEMAND | 6367 |
| WATER HEATING DEMAND | 1965 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01006141 (Wallace) |
| ENERGY CONSUMPTION POTENTIAL | 77.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Stirling |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Peak Power: 2.62; Orientation: South West; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 7 |
| CONSTITUENCY | 00RGMD |
| CONSTITUENCY LABEL | Castle |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01013078 (Cornton - 03) |
| CREATED AT | 29/06/2016 11:10:54 |
| REPORT REFERENCE NUMBER | 7400-3917-0429-5225-1663 |
| Source file | Q2 2016.csv |
| Address display | 142A STRATHMORE DRIVE , CORNTON , STIRLING |
| Nation | scotland |