Energy Performance Certificate
16A LOANHEAD STREET , KILMARNOCK, KA1 3AU
Energy rating
Current: 60 D | Potential: 77 C
Environmental impact (CO₂)
Current: 52
| Potential: 75
| Field | Value |
|---|---|
| Id | 4103158 |
| BUILDING REFERENCE NUMBER | 1001391717 |
| OSG REFERENCE NUMBER | 127052386 |
| ADDRESS1 | 16A LOANHEAD STREET |
| ADDRESS2 | — |
| ADDRESS3 | KILMARNOCK |
| POSTCODE | KA1 3AU |
| INSPECTION DATE | 2016-06-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-17 |
| ENERGY CONSUMPTION CURRENT | 268.00 |
| TOTAL FLOOR AREA | 130 |
| 3 YR ENERGY COST CURRENT | 4278.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1899.0000 |
| CURRENT ENERGY EFFICIENCY | 60 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 77 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 52 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 75 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 49.00 |
| IMPROVEMENTS | Description: Replacement glazing units; Indicative Cost: £1,000 - £1,400; Typical Saving: 52; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 84; Energy Rating after improvement: D 62; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 453; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 45; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 73; Green Deal Eligible: N | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed) |
| WALL ENERGY EFF | Poor | Poor |
| WALL ENV EFF | Poor | Poor |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 29% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.40 |
| CO2 EMISSIONS POTENTIAL | 3.10 |
| HEATING COST CURRENT | 3552.0000 |
| HEATING COST POTENTIAL | 1821.0000 |
| HOT WATER COST CURRENT | 318.00 |
| HOT WATER COST POTENTIAL | 321.00 |
| LIGHTING COST CURRENT | 408.00 |
| LIGHTING COST POTENTIAL | 237.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 17701 |
| WATER HEATING DEMAND | 2181 |
| IMPACT LOFT INSULATION | -1399 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -7575 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.04 |
| DATA ZONE | S01001363 (Piersland) |
| ENERGY CONSUMPTION POTENTIAL | 140.00 |
| EXTENSION COUNT | 1 |
| FIXED LIGHTING OUTLETS COUNT | 14 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 29.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | no corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | East Ayrshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 1 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QKMD |
| CONSTITUENCY LABEL | Kilmarnock East and Hurlford |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007978 (Piersland - 02) |
| CREATED AT | 17/06/2016 12:23:26 |
| REPORT REFERENCE NUMBER | 7300-1987-0129-4101-1663 |
| Source file | Q2 2016.csv |
| Address display | 16A LOANHEAD STREET , KILMARNOCK |
| Nation | scotland |