Energy Performance Certificate

29 GADLE BRAES , PETERHEAD, AB42 1PJ

EPC Report

Energy rating

Current: 66 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 64 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 79 Potential: 79
Field Value
Id 4475349
BUILDING REFERENCE NUMBER 1001266334
OSG REFERENCE NUMBER 151007871
ADDRESS1 29 GADLE BRAES
ADDRESS2
ADDRESS3 PETERHEAD
POSTCODE AB42 1PJ
INSPECTION DATE 2015-07-30
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-08-02
ENERGY CONSUMPTION CURRENT 292.00
TOTAL FLOOR AREA 63
3 YR ENERGY COST CURRENT 2286.0000
3 YR ENERGY SAVINGS POTENTIAL 813.0000
CURRENT ENERGY EFFICIENCY 66
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 77
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 64
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 79
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 51.00
IMPROVEMENTS Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 90; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 19; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 76; Green Deal Eligible: N | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 106; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 58; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 79; Green Deal Eligible: Y |
WALL DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALL ENERGY EFF Poor
WALL ENV EFF Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 3.20
CO2 EMISSIONS POTENTIAL 1.30
HEATING COST CURRENT 1767.0000
HEATING COST POTENTIAL 1050.0000
HOT WATER COST CURRENT 318.00
HOT WATER COST POTENTIAL 288.00
LIGHTING COST CURRENT 201.00
LIGHTING COST POTENTIAL 135.00
ALTERNATIVE IMPROVEMENTS Description: External insulation with cavity wall insulation | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 8303
WATER HEATING DEMAND 1898
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION -1895
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1950-1964
FLOOR HEIGHT 2.34
DATA ZONE S01000482 (Peterhead Harbour)
ENERGY CONSUMPTION POTENTIAL 172.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
LOW ENERGY LIGHTING 50.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR no corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Aberdeenshire
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (social)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QBME
CONSTITUENCY LABEL Peterhead North and Rattray
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01007087 (Peterhead Harbour - 07)
CREATED AT 02/08/2016 12:51:32
REPORT REFERENCE NUMBER 7204-1012-3203-3665-6904
Source file Q3 2016.csv
Address display 29 GADLE BRAES , PETERHEAD
Nation scotland