Energy Performance Certificate
5 NEWMANSWALLS AVENUE , MONTROSE, DD10 9DD
Energy rating
Current: 77 C | Potential: 88 B
Environmental impact (CO₂)
Current: 75
| Potential: 87
| Field | Value |
|---|---|
| Id | 4105415 |
| BUILDING REFERENCE NUMBER | 1001680866 |
| OSG REFERENCE NUMBER | 117073226 |
| ADDRESS1 | 5 NEWMANSWALLS AVENUE |
| ADDRESS2 | — |
| ADDRESS3 | MONTROSE |
| POSTCODE | DD10 9DD |
| INSPECTION DATE | 2016-06-22 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-24 |
| ENERGY CONSUMPTION CURRENT | 173.00 |
| TOTAL FLOOR AREA | 102 |
| 3 YR ENERGY COST CURRENT | 2232.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 225.0000 |
| CURRENT ENERGY EFFICIENCY | 77 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 88 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 75 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 87 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 30.00 |
| IMPROVEMENTS | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 34; Energy Rating after improvement: C 79; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 267; Energy Rating after improvement: B 88; Environmental Rating after improvement: B 87; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 41; Energy Rating after improvement: C 78; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.10 |
| CO2 EMISSIONS POTENTIAL | 1.30 |
| HEATING COST CURRENT | 1746.0000 |
| HEATING COST POTENTIAL | 1623.0000 |
| HOT WATER COST CURRENT | 294.00 |
| HOT WATER COST POTENTIAL | 192.00 |
| LIGHTING COST CURRENT | 192.00 |
| LIGHTING COST POTENTIAL | 192.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 9700 |
| WATER HEATING DEMAND | 2018 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1976-1983 |
| FLOOR HEIGHT | 2.37 |
| DATA ZONE | S01000691 (Montrose North) |
| ENERGY CONSUMPTION POTENTIAL | 99.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 12 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 5 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 5 |
| LOCAL AUTHORITY LABEL | Angus |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (social) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QCMH |
| CONSTITUENCY LABEL | Montrose and District |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01007219 (Montrose North - 05) |
| CREATED AT | 24/06/2016 06:09:37 |
| REPORT REFERENCE NUMBER | 6600-2828-0029-1126-1663 |
| Source file | Q2 2016.csv |
| Address display | 5 NEWMANSWALLS AVENUE , MONTROSE |
| Nation | scotland |