Energy Performance Certificate

53 WALLACE CRESCENT , ROSLIN, EH25 9LN

EPC Report

Energy rating

Current: 74 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 74 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 78 Potential: 78
Field Value
Id 4122979
BUILDING REFERENCE NUMBER 1000148116
OSG REFERENCE NUMBER 120007404
ADDRESS1 53 WALLACE CRESCENT
ADDRESS2
ADDRESS3 ROSLIN
POSTCODE EH25 9LN
INSPECTION DATE 2016-06-07
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2017-04-21
ENERGY CONSUMPTION CURRENT 208.00
TOTAL FLOOR AREA 63
3 YR ENERGY COST CURRENT 1734.0000
3 YR ENERGY SAVINGS POTENTIAL 201.0000
CURRENT ENERGY EFFICIENCY 74
CURRENT ENERGY RATING C
POTENTIAL ENERGY EFFICIENCY 77
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 74
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 78
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 37.00
IMPROVEMENTS Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 68; Energy Rating after improvement: C 77; Environmental Rating after improvement: C 78; Green Deal Eligible: Y |
WALL DESCRIPTION Solid brick, with external insulation
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 2.30
CO2 EMISSIONS POTENTIAL 0.30
HEATING COST CURRENT 1311.0000
HEATING COST POTENTIAL 1107.0000
HOT WATER COST CURRENT 288.00
HOT WATER COST POTENTIAL 291.00
LIGHTING COST CURRENT 135.00
LIGHTING COST POTENTIAL 135.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 6322
WATER HEATING DEMAND 1900
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1930-1949
FLOOR HEIGHT 2.62
DATA ZONE S01004158 (Rural South Midlothian)
ENERGY CONSUMPTION POTENTIAL 178.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR no corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Midlothian
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (social)
TRANSACTION TYPE ECO assessment
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QWMD
CONSTITUENCY LABEL Midlothian West
WIND TURBINE COUNT 0
BUILT FORM Semi-Detached
PROPERTY TYPE Flat
DATA ZONE 2011 S01010959 (Roslin and Bilston - 03)
CREATED AT 21/04/2017 15:53:17
REPORT REFERENCE NUMBER 6100-9431-0829-2001-1663
Source file Q2 2017.csv
Address display 53 WALLACE CRESCENT , ROSLIN
Nation scotland