Energy Performance Certificate

79 Ferguson Way , Knightsridge , Livingston, EH54 8JF

EPC Report

Energy rating

Current: 68 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 63 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 79 Potential: 79
Field Value
Id 4099030
BUILDING REFERENCE NUMBER 1001113446
OSG REFERENCE NUMBER 200004100913
ADDRESS1 79 Ferguson Way
ADDRESS2 Knightsridge
ADDRESS3 Livingston
POSTCODE EH54 8JF
INSPECTION DATE 2016-06-08
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-09
ENERGY CONSUMPTION CURRENT 260.00
TOTAL FLOOR AREA 86
3 YR ENERGY COST CURRENT 2739.0000
3 YR ENERGY SAVINGS POTENTIAL 426.0000
CURRENT ENERGY EFFICIENCY 68
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 83
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 63
CURRENT ENVIRONMENTAL RATING D
ENVIRONMENT IMPACT POTENTIAL 79
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 46.00
IMPROVEMENTS Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 252; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 48; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 66; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Flue gas heat recovery device in conjunction with boiler; Indicative Cost: £400 - £900; Typical Saving: 28; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 70; Green Deal Eligible: Y |
WALL DESCRIPTION System built, as built, no insulation (assumed)
WALL ENERGY EFF Very Poor
WALL ENV EFF Very Poor
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 93% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 4.00
CO2 EMISSIONS POTENTIAL 1.60
HEATING COST CURRENT 2196.0000
HEATING COST POTENTIAL 1890.0000
HOT WATER COST CURRENT 363.00
HOT WATER COST POTENTIAL 243.00
LIGHTING COST CURRENT 180.00
LIGHTING COST POTENTIAL 180.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Micro CHP | Cavity, internal or external wall insulation
LZC ENERGY SOURCES
SPACE HEATING DEMAND 11500
WATER HEATING DEMAND 2159
IMPACT LOFT INSULATION -514
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 1965-1975
FLOOR HEIGHT 2.3
DATA ZONE S01006450 (Knightsridge)
ENERGY CONSUMPTION POTENTIAL 155.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 14
LOW ENERGY LIGHTING 93.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 4
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 4
LOCAL AUTHORITY LABEL West Lothian
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00RHMC
CONSTITUENCY LABEL Livingston North
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE House
DATA ZONE 2011 S01013335 (Knightsridge - 06)
CREATED AT 09/06/2016 14:37:50
REPORT REFERENCE NUMBER 6100-7184-0329-0104-1663
Source file Q2 2016.csv
Address display 79 Ferguson Way , Knightsridge , Livingston
Nation scotland