Energy Performance Certificate
79 Ferguson Way , Knightsridge , Livingston, EH54 8JF
Energy rating
Current: 68 D | Potential: 83 B
Environmental impact (CO₂)
Current: 63
| Potential: 79
| Field | Value |
|---|---|
| Id | 4099030 |
| BUILDING REFERENCE NUMBER | 1001113446 |
| OSG REFERENCE NUMBER | 200004100913 |
| ADDRESS1 | 79 Ferguson Way |
| ADDRESS2 | Knightsridge |
| ADDRESS3 | Livingston |
| POSTCODE | EH54 8JF |
| INSPECTION DATE | 2016-06-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-09 |
| ENERGY CONSUMPTION CURRENT | 260.00 |
| TOTAL FLOOR AREA | 86 |
| 3 YR ENERGY COST CURRENT | 2739.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 426.0000 |
| CURRENT ENERGY EFFICIENCY | 68 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 63 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 46.00 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 252; Energy Rating after improvement: B 83; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 48; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 66; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Flue gas heat recovery device in conjunction with boiler; Indicative Cost: £400 - £900; Typical Saving: 28; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 70; Green Deal Eligible: Y | |
| WALL DESCRIPTION | System built, as built, no insulation (assumed) |
| WALL ENERGY EFF | Very Poor |
| WALL ENV EFF | Very Poor |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 93% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.00 |
| CO2 EMISSIONS POTENTIAL | 1.60 |
| HEATING COST CURRENT | 2196.0000 |
| HEATING COST POTENTIAL | 1890.0000 |
| HOT WATER COST CURRENT | 363.00 |
| HOT WATER COST POTENTIAL | 243.00 |
| LIGHTING COST CURRENT | 180.00 |
| LIGHTING COST POTENTIAL | 180.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Micro CHP | Cavity, internal or external wall insulation |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 11500 |
| WATER HEATING DEMAND | 2159 |
| IMPACT LOFT INSULATION | -514 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01006450 (Knightsridge) |
| ENERGY CONSUMPTION POTENTIAL | 155.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 15 |
| LOW ENERGY FIXED LIGHT COUNT | 14 |
| LOW ENERGY LIGHTING | 93.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | West Lothian |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00RHMC |
| CONSTITUENCY LABEL | Livingston North |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01013335 (Knightsridge - 06) |
| CREATED AT | 09/06/2016 14:37:50 |
| REPORT REFERENCE NUMBER | 6100-7184-0329-0104-1663 |
| Source file | Q2 2016.csv |
| Address display | 79 Ferguson Way , Knightsridge , Livingston |
| Nation | scotland |