Energy Performance Certificate
100 MORISTON COURT , GRANGEMOUTH, FK3 0JL
Energy rating
Current: 29 F | Potential: 62 D
Environmental impact (CO₂)
Current: 39
| Potential: 65
| Field | Value |
|---|---|
| Id | 4108003 |
| BUILDING REFERENCE NUMBER | 1001944305 |
| OSG REFERENCE NUMBER | 136049568 |
| ADDRESS1 | 100 MORISTON COURT |
| ADDRESS2 | — |
| ADDRESS3 | GRANGEMOUTH |
| POSTCODE | FK3 0JL |
| INSPECTION DATE | 2016-06-07 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-08 |
| ENERGY CONSUMPTION CURRENT | 454.00 |
| TOTAL FLOOR AREA | 88 |
| 3 YR ENERGY COST CURRENT | 5994.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2049.0000 |
| CURRENT ENERGY EFFICIENCY | 29 |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY EFFICIENCY | 62 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 39 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 65 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 77.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 18; Energy Rating after improvement: F 36; Environmental Rating after improvement: E 44; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,600 - £2,400; Typical Saving: 274; Energy Rating after improvement: E 44; Environmental Rating after improvement: E 51; Green Deal Eligible: Y | Description: High performance external doors; Indicative Cost: £1,000; Typical Saving: 41; Energy Rating after improvement: E 52; Environmental Rating after improvement: D 56; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 250; Energy Rating after improvement: D 62; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 145; Energy Rating after improvement: E 50; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 204; Energy Rating after improvement: F 35; Environmental Rating after improvement: E 43; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 6.80 |
| CO2 EMISSIONS POTENTIAL | 3.20 |
| HEATING COST CURRENT | 4821.0000 |
| HEATING COST POTENTIAL | 3246.0000 |
| HOT WATER COST CURRENT | 1002.00 |
| HOT WATER COST POTENTIAL | 528.00 |
| LIGHTING COST CURRENT | 171.00 |
| LIGHTING COST POTENTIAL | 171.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 10487 |
| WATER HEATING DEMAND | 2183 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1984-1991 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01002439 (Bowhouse) |
| ENERGY CONSUMPTION POTENTIAL | 242.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 8 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Falkirk |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QQMB |
| CONSTITUENCY LABEL | Grangemouth |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | End-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009238 (Grangemouth - Bowhouse - 01) |
| CREATED AT | 08/06/2016 13:22:29 |
| REPORT REFERENCE NUMBER | 5900-6433-0429-7100-1663 |
| Source file | Q2 2016.csv |
| Address display | 100 MORISTON COURT , GRANGEMOUTH |
| Nation | scotland |