Energy Performance Certificate

PF2 , 6 BALFOUR PLACE , EDINBURGH, EH6 5DW

EPC Report

Energy rating

Current: 52 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 46 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 72 Potential: 72
Field Value
Id 4091132
BUILDING REFERENCE NUMBER 1000286225
OSG REFERENCE NUMBER 906338779
ADDRESS1 PF2
ADDRESS2 6 BALFOUR PLACE
ADDRESS3 EDINBURGH
POSTCODE EH6 5DW
INSPECTION DATE 2016-06-02
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-05
ENERGY CONSUMPTION CURRENT 403.00
TOTAL FLOOR AREA 66
3 YR ENERGY COST CURRENT 3306.0000
3 YR ENERGY SAVINGS POTENTIAL 1449.0000
CURRENT ENERGY EFFICIENCY 52
CURRENT ENERGY RATING E
POTENTIAL ENERGY EFFICIENCY 73
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 46
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 72
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 74.00
IMPROVEMENTS Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 39; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 309; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 108; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 25; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 70; Green Deal Eligible: N |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALL ENERGY EFF Poor
WALL ENV EFF Poor
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 4.90
CO2 EMISSIONS POTENTIAL 2.40
HEATING COST CURRENT 2742.0000
HEATING COST POTENTIAL 1419.0000
HOT WATER COST CURRENT 327.00
HOT WATER COST POTENTIAL 297.00
LIGHTING COST CURRENT 237.00
LIGHTING COST POTENTIAL 141.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 12860
WATER HEATING DEMAND 1951
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -5025
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 3.16
DATA ZONE S01002254 (Bonnington and Pilrig)
ENERGY CONSUMPTION POTENTIAL 208.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 2
LOW ENERGY LIGHTING 33.00
FLOOR LEVEL ground floor
FLAT TOP STOREY 00
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2106
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
NUMBER OPEN FIREPLACES 1
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE marketed sale
UNHEATED CORRIDOR LENGTH 15.4
CONSTITUENCY 00QPMM
CONSTITUENCY LABEL Leith Walk
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008815 (Pilrig - 03)
CREATED AT 05/06/2016 18:48:54
REPORT REFERENCE NUMBER 5200-0822-0629-8002-1663
Source file Q2 2016.csv
Address display PF2 , 6 BALFOUR PLACE , EDINBURGH
Nation scotland