Energy Performance Certificate
SHALOM , LOCHDON , ISLE OF MULL, PA64 6AP
Energy rating
Current: 37 F | Potential: 87 B
Environmental impact (CO₂)
Current: 30
| Potential: 68
| Field | Value |
|---|---|
| Id | 4088217 |
| BUILDING REFERENCE NUMBER | 1000016295 |
| OSG REFERENCE NUMBER | 125067448 |
| ADDRESS1 | SHALOM |
| ADDRESS2 | LOCHDON |
| ADDRESS3 | ISLE OF MULL |
| POSTCODE | PA64 6AP |
| INSPECTION DATE | 2016-06-29 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-06-29 |
| ENERGY CONSUMPTION CURRENT | 564.00 |
| TOTAL FLOOR AREA | 89 |
| 3 YR ENERGY COST CURRENT | 5322.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1488.0000 |
| CURRENT ENERGY EFFICIENCY | 37 |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY EFFICIENCY | 87 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 30 |
| CURRENT ENVIRONMENTAL RATING | F |
| ENVIRONMENT IMPACT POTENTIAL | 68 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 95.00 |
| IMPROVEMENTS | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 99; Energy Rating after improvement: E 40; Environmental Rating after improvement: F 32; Green Deal Eligible: Y | Description: Wind turbine; Indicative Cost: £15,000 - £25,000; Typical Saving: 590; Energy Rating after improvement: B 87; Environmental Rating after improvement: D 68; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 23; Energy Rating after improvement: E 50; Environmental Rating after improvement: E 39; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 218; Energy Rating after improvement: E 48; Environmental Rating after improvement: E 39; Green Deal Eligible: Y | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 21; Energy Rating after improvement: E 49; Environmental Rating after improvement: E 39; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 107; Energy Rating after improvement: E 54; Environmental Rating after improvement: E 42; Green Deal Eligible: Y | Description: High performance external doors; Indicative Cost: £1,000; Typical Saving: 27; Energy Rating after improvement: D 55; Environmental Rating after improvement: E 43; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 255; Energy Rating after improvement: D 65; Environmental Rating after improvement: E 50; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Mostly double glazing |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Automatic charge control |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 8.50 |
| CO2 EMISSIONS POTENTIAL | 5.00 |
| HEATING COST CURRENT | 4137.0000 |
| HEATING COST POTENTIAL | 3162.0000 |
| HOT WATER COST CURRENT | 897.00 |
| HOT WATER COST POTENTIAL | 480.00 |
| LIGHTING COST CURRENT | 288.00 |
| LIGHTING COST POTENTIAL | 192.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 13662 |
| WATER HEATING DEMAND | 2190 |
| IMPACT LOFT INSULATION | -990 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.4 |
| DATA ZONE | S01000820 (Mull, Iona, Coll and Tiree) |
| ENERGY CONSUMPTION POTENTIAL | 233.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 6 |
| LOW ENERGY LIGHTING | 50.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Argyll and Bute |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2402 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Unknown |
| MULTI GLAZE PROPORTION | 90 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QDMD |
| CONSTITUENCY LABEL | Oban South and the Isles |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01007288 (Mull, Iona, Coll and Tiree - 05) |
| CREATED AT | 29/06/2016 16:42:46 |
| REPORT REFERENCE NUMBER | 5000-2112-0629-7029-1663 |
| Source file | Q2 2016.csv |
| Address display | SHALOM , LOCHDON , ISLE OF MULL |
| Nation | scotland |