Energy Performance Certificate

New House Tighnamara Hotel , Main Street , Stranraer, DG9 9JF

EPC Report

Energy rating

Current: 57 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 51 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 72 Potential: 72
Field Value
Id 4120124
BUILDING REFERENCE NUMBER 1234986214
OSG REFERENCE NUMBER
ADDRESS1 New House Tighnamara Hotel
ADDRESS2 Main Street
ADDRESS3 Stranraer
POSTCODE DG9 9JF
INSPECTION DATE 2016-06-27
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-06-30
ENERGY CONSUMPTION CURRENT 215.00
TOTAL FLOOR AREA 136
3 YR ENERGY COST CURRENT 4125.0000
3 YR ENERGY SAVINGS POTENTIAL 1194.0000
CURRENT ENERGY EFFICIENCY 57
CURRENT ENERGY RATING D
POTENTIAL ENERGY EFFICIENCY 78
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 51
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 72
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 52.00
IMPROVEMENTS Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 260; Energy Rating after improvement: D 66; Environmental Rating after improvement: D 61; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 45; Energy Rating after improvement: C 70; Environmental Rating after improvement: D 65; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £70; Typical Saving: 51; Energy Rating after improvement: D 67; Environmental Rating after improvement: D 62; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 41; Energy Rating after improvement: C 69; Environmental Rating after improvement: D 63; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 279; Energy Rating after improvement: C 78; Environmental Rating after improvement: C 72; Green Deal Eligible: Y |
WALL DESCRIPTION Timber frame, as built, insulated (assumed)
WALL ENERGY EFF Good
WALL ENV EFF Good
ROOF DESCRIPTION Pitched, no insulation | Roof room(s), insulated (assumed)
ROOF ENERGY EFF Very Poor | Good
ROOF ENV EFF Very Poor | Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 7.10
CO2 EMISSIONS POTENTIAL 3.00
HEATING COST CURRENT 3027.0000
HEATING COST POTENTIAL 2163.0000
HOT WATER COST CURRENT 666.00
HOT WATER COST POTENTIAL 531.00
LIGHTING COST CURRENT 432.00
LIGHTING COST POTENTIAL 237.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 14007
WATER HEATING DEMAND 3782
IMPACT LOFT INSULATION -3782
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 2003-2007
FLOOR HEIGHT 2.4
DATA ZONE S01000901 (Kirkmaiden)
ENERGY CONSUMPTION POTENTIAL 112.00
EXTENSION COUNT 1
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 3
LOW ENERGY LIGHTING 18.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 1
NUMBER HABITABLE ROOMS 4
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 4
LOCAL AUTHORITY LABEL Dumfries and Galloway
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL oil (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE non marketed sale
UNHEATED CORRIDOR LENGTH
CONSTITUENCY 00QHMB
CONSTITUENCY LABEL Wigtown West
WIND TURBINE COUNT 0
BUILT FORM Detached
PROPERTY TYPE House
DATA ZONE 2011 S01007500 (Rhins South - 02)
CREATED AT 30/06/2016 20:58:38
REPORT REFERENCE NUMBER 4902-7832-3629-5421-1663
Source file Q2 2016.csv
Address display New House Tighnamara Hotel , Main Street , Stranraer
Nation scotland