Energy Performance Certificate
ORCHARD COTTAGE , MAIN STREET , DUNBAR, EH42 1XL
Energy rating
Current: 44 E | Potential: 74 C
Environmental impact (CO₂)
Current: 37
| Potential: 66
| Field | Value |
|---|---|
| Id | 4474255 |
| BUILDING REFERENCE NUMBER | 1001208524 |
| OSG REFERENCE NUMBER | 138022948 |
| ADDRESS1 | ORCHARD COTTAGE |
| ADDRESS2 | MAIN STREET |
| ADDRESS3 | DUNBAR |
| POSTCODE | EH42 1XL |
| INSPECTION DATE | 2016-06-30 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-07-14 |
| ENERGY CONSUMPTION CURRENT | 274.00 |
| TOTAL FLOOR AREA | 157 |
| 3 YR ENERGY COST CURRENT | 5460.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 2268.0000 |
| CURRENT ENERGY EFFICIENCY | 44 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 74 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 37 |
| CURRENT ENVIRONMENTAL RATING | F |
| ENVIRONMENT IMPACT POTENTIAL | 66 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 70.00 |
| IMPROVEMENTS | Description: Cavity wall insulation; Indicative Cost: £500 - £1,500; Typical Saving: 114; Energy Rating after improvement: E 47; Environmental Rating after improvement: E 40; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 74; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 64; Energy Rating after improvement: D 64; Environmental Rating after improvement: D 55; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 219; Energy Rating after improvement: E 54; Environmental Rating after improvement: E 46; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 116; Energy Rating after improvement: D 58; Environmental Rating after improvement: E 50; Green Deal Eligible: Y | Description: Draughtproofing; Indicative Cost: £80 - £120; Typical Saving: 21; Energy Rating after improvement: D 60; Environmental Rating after improvement: E 52; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £50; Typical Saving: 39; Energy Rating after improvement: D 61; Environmental Rating after improvement: E 53; Green Deal Eligible: N | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 57; Energy Rating after improvement: D 60; Environmental Rating after improvement: E 52; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 51; Energy Rating after improvement: D 65; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 278; Energy Rating after improvement: C 74; Environmental Rating after improvement: D 66; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, insulated (assumed) | Cavity wall, as built, no insulation (assumed) | Sandstone or limestone, as built, no insulation (assumed) |
| WALL ENERGY EFF | Good | Poor | Very Poor |
| WALL ENV EFF | Good | Poor | Very Poor |
| ROOF DESCRIPTION | Flat, insulated | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good | Good |
| ROOF ENV EFF | Good | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A | N/A |
| FLOOR ENV EFF | N/A | N/A |
| WINDOWS DESCRIPTION | Description: Partial secondary glazing |
| WINDOWS ENERGY EFF | Poor |
| WINDOWS ENV EFF | Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, oil |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 41% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 11.00 |
| CO2 EMISSIONS POTENTIAL | 5.60 |
| HEATING COST CURRENT | 4497.0000 |
| HEATING COST POTENTIAL | 2664.0000 |
| HOT WATER COST CURRENT | 573.00 |
| HOT WATER COST POTENTIAL | 279.00 |
| LIGHTING COST CURRENT | 390.00 |
| LIGHTING COST POTENTIAL | 249.00 |
| ALTERNATIVE IMPROVEMENTS | Description: External insulation with cavity wall insulation | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 24090 |
| WATER HEATING DEMAND | 3485 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | -1885 |
| IMPACT SOLID WALL INSULATION | -3608 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.57 |
| DATA ZONE | S01001652 (IZ Fifteen) |
| ENERGY CONSUMPTION POTENTIAL | 124.00 |
| EXTENSION COUNT | 2 |
| FIXED LIGHTING OUTLETS COUNT | 17 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 41.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 6 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 6 |
| LOCAL AUTHORITY LABEL | East Lothian |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | oil (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 50 |
| GLAZED TYPE | secondary glazing |
| NUMBER OPEN FIREPLACES | 1 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QMMG |
| CONSTITUENCY LABEL | Dunbar and East Linton |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01008278 (IZ20 - 02) |
| CREATED AT | 14/07/2016 12:10:24 |
| REPORT REFERENCE NUMBER | 4200-3005-0829-3172-1663 |
| Source file | Q3 2016.csv |
| Address display | ORCHARD COTTAGE , MAIN STREET , DUNBAR |
| Nation | scotland |